TO STOP SCRUBBING
1. Press the brush motor switch (#1) on the console
touch pad. The motors will stop and the scrub
deck will raise to the park position. Nothing
further needs to be done. After 15 seconds the
squeegee will lift and the vacuum motor will run
an additional 15 seconds. These delays are
programmed to avoid leaving water between the
location the brush lifted and the squeegee lifted,
and to clean the recovery hose.
2. Apply brake to stop machine.
3. Turn key switch off.
4. Set parking brake.
DOUBLE SCRUB
Floors which are heavily soiled or have thick
accumulations of floor finish may not clean
sufficiently with one pass. In these cases it will be
necessary to double scrub.
To double scrub, make the first pass over the surface
being cleaned with the squeegee up, the solution on,
and brushes down. This allows the solution to stay in
contact with the soil while loosening the surface
accumulation with the brushes. Allow time for the
first application to stay in contact with the floor.
Length of time between the first and second pass
depends on amount of accumulation and type of
chemical being used. A second scrubbing with the
squeegee down again the solution and brushes on
will further loosen the soil. The additional application
of solution will further assist the difficult cleaning job.
If desired the side squeegee may be locked in the up
position by raising squeegee and rotating latch.

EMPTYING AND CLEANING TANKS

RECOVERY TANK
1. Pull the solution lever all the way up to stop
solution flow if scrubbing is complete. Otherwise
raising the scrub deck will stop solution flow.
2. Touch the scrub brush switch to raise the scrub
deck, stop the brush motors, raise the squeegee
and stop the vacuum.
3. Park the QUICK© next to a floor drain.
4. Turn off the key switch and set the machine
parking brakes.
5. Unhook the drain hose from retainer. Unscrew T-
handle on plug enough to loosen plug and lower
hose in direction of drain. Stand behind end of
hose. Recovered solution will come out with
force. Slowly remove plug from drain hose.
6. Recovery tank should be flushed out with clean
water on a daily basis. Do not use water hotter
than 140°F (60°C) to clean tank. Damage to tank
may occur.
7. Clean around float shut off device and check for
free movement of float.
8. Large debris or compacted dirt may be removed
by clean out cap located on left side at rear.
9. Replace plug and secure drain hose in bracket.
10. If machine is to be stored, leave recovery tank
cover open and drain cap off.
SOLUTION TANK
1. Drain solution tank by lowering clear vinyl tube
from hanging bracket. Unscrew T-handle and
remove plug.
2. Flush tank of all chemical solution.
3. Run several gallons of clean water through
system.
NOTE: Never allow solution to remain in tank.
Damage to tank, seals and valves could occur.