EMPTYING AND CLEANING THE TANKS

Empty the Recovery Tank directly into the floor
drain via drain hose. After each use, rinse tank
(including the float shut-off) with fresh water.
Periodically inspect the recovery tank and
decontaminate if necessary, using a Hospital
Grade Virucide or a 1-10 bleach to water
solution. This will dissipate the exposure to
blood born or infectious contamination. Waste
water should be disposed of properly. Clean the
inside of the recovert dome also.
Empty the Solution Tank by detaching the sight
hose and empty directly into the floor drain.
Flush the Solution System with 1 gallon of
CLEAN water.
SOLUTION TO REMAIN IN TANK WHEN NOT
IN USE; NOR ALLOW UNUSED SOLUTION
TO REMAIN IN THE SOLUTION TANK WHEN
IN STORAGE. INSPECT AND CLEAN THE
FILTER LOCATED UNDER THE MACHINE
NEAR THE PUMP. REMOVE AND RINSE
WITH HOT WATER.
4-1
NEVER ALLOW
RECOVERED
86039020 VOYAGER E 08/20/07
To prevent clogged jets due to alkaline build-up,
the spray system should be flushed with 1
gallon of clean hot water at the end of each
work day. The VOYAGER-E is equipped with
"quick change" jets that can be easily removed
for cleaning. To remove – push jet in and rotate.
Do not use pins or wire to remove obstruction
as this will damage jet and alter spray pattern.
MANIFOLD ASSEMBLY
QUICK CHANGE JETS