Scan Image Distortion Adjustment; Scanner (Reading) Unit Parallelism Adjustment - Sharp MX-1810U Service Manual

Hide thumbs Also See for MX-1810U:
Table of Contents

Advertisement

(Reference adjustment value)
1 scale/1 (When the set value is changed by 1, shift is made by 1
scale.)
If there is a considerable difference in color shift in the square and
at the center area, perform the adjustment.
Select an adjustment item (OFF SET X F / OFF SET X R / OFF
SET X S), and change the adjustment value to adjust.
OFF SET X F: F side main scanning direction registration offset set
value (The color shift on the F side and at the center area is
changed.)
OFF SET X D: R side main scanning direction registration offset set
value (The color shift on the R side and at the center area is
changed.)
OFF SET X S: Sub scanning direction registration offset set value
(Color is shifted to the sub scanning direction overall.)
When the adjustment value of OFF SET X F and OFF SET X R are
changed, the color at the center area will be affected. Consider this
when executing the adjustment.
(Adjustment conditions and method)
To adjust evenly overall, adjust so that the color shifts on the F side,
the R aide and at the center are of the same level.
To adjust with the center area most focused, adjust so that the color
shift at the center becomes smaller than that on the F side and the
R side.
When the offset adjustment value is 0, if the color registration
adjustment (automatic adjustment) is performed, the color shift on
the F side and that on the R side are automatically adjusted to be
smaller than that on the center area.
Display/Item
Content
A
CYAN
Image registration adjustment
(FRONT)
value (Main scanning
direction) (Cyan) (F side)
B
CYAN
Image registration adjustment
(REAR)
value (Main scanning
direction) (Cyan) (R side)
C
MAGENTA
Image registration adjustment
(FRONT)
value (Main scanning
direction) (Magenta) (F side)
D
MAGENTA
Image registration adjustment
(REAR)
value (Main scanning
direction) (Magenta) (R side)
E
YELLOW
Image registration adjustment
(FRONT)
value (Main scanning
direction) (Yellow) (F side)
F
YELLOW
Image registration adjustment
(REAR)
value (Main scanning
direction) (Yellow) (R side)
G
CYAN
Image registration adjustment
(SUB)
value (Sub scanning
direction) (Cyan)
H
MAGENTA
Image registration adjustment
(SUB)
value (Sub scanning
direction) (Magenta)
I
YELLOW
Image registration adjustment
(SUB)
value (Sub scanning
direction) (Yellow)
J
OFFSET
Image registration offset
CF
adjustment value (Main
scanning direction) (Cyan)
(F side)
K
OFFSET
Image registration offset
CR
adjustment value (Main
scanning direction) (Cyan)
(R side)
Adjustment
Default
value range
value
1 - 199
100
1 - 199
100
1 - 199
100
1 - 199
100
1 - 199
100
1 - 199
100
1 - 199
100
1 - 199
100
1 - 199
100
1 - 199
100
1 - 199
100
MX-3610N ADJUSTMENTS AND SETTINGS 4 – 21
Display/Item
Content
L
OFFSET
Image registration offset
MF
adjustment value (Main
scanning direction) (Magenta)
(F side)
M
OFFSET
Image registration offset
MR
adjustment value (Main
scanning direction) (Magenta)
(R side)
N
OFFSET
Image registration offset
YF
adjustment value (Main
scanning direction) (Yellow)
(F side)
O
OFFSET
Image registration offset
YR
adjustment value (Main
scanning direction) (Yellow)
(R side)
P
OFFSET
Image registration offset
CS
adjustment value (Sub
scanning direction) (Cyan)
Q
OFFSET
Image registration offset
MS
adjustment value (Sub
scanning direction) (Magenta)
R
OFFSET
Image registration offset
YS
adjustment value (Sub
scanning direction) (Yellow)
ADJ 6
Scan image distortion
adjustment
(Document table mode)
This adjustment must be performed in the following cases:
* When the scanner (reading) section is disassembled.
* When the copy image is distorted.
6-A
Scanner (reading) unit parallelism
adjustment
Before execution of this adjustment, remove the document table
glass.
1)
Remove the lamp unit, and then loosen the screws which are
fixing the scanner unit A and the drive wire. Release the scan-
ner unit A from the drive wire.
Adjustment
Default
value range
value
1 - 199
100
1 - 199
100
1 - 199
100
1 - 199
100
1 - 199
100
1 - 199
100
1 - 199
100