Sharp MX-1810U Service Manual page 74

Hide thumbs Also See for MX-1810U:
Table of Contents

Advertisement

(2) 23cpm/26cpm/31cpm machine
F001
F003
Signal name
Name
F1
Fuse
F2
Fuse
F001
Fuse
F003
Fuse
F101
Fuse
F401
Fuse
F201
Fuse
F202
Fuse
F203
Fuse
F204
Fuse
F205
Fuse
Signal name
Name
TS LM
Thermostat LM
TS UM
Thermostat UM
TS US
Thermostat US
F401
F202
F205
100v series
200v series
20A 250V
T10AH 250V
-
T10AH 250V
T12AH 250V
T6.3AH 250V
T3.15AH 250V
T3.15AH 250V
F10AH 250V (F101)
F5AH 250V (F101)
F3.15AH 250V (F401)
F2AH 250V (F401)
6.3A
6.3A
6.3A
6.3A
6.3A
6.3A
6.3A
6.3A
4.0A
4.0A
Type
Mechanical thermostat
Shuts down the heater lamp (HL_LM) circuit when the fusing section is overheated.
Mechanical thermostat
Shuts down the heater lamp (HL_UM) circuit when the fusing section is overheated.
(Center section)
Mechanical thermostat
Shuts down the heater lamp (HL_US) circuit when the fusing section is overheated.
(Edge section)
MX-3610N EXTERNAL VIEW AND INTERNAL STRUCTURE 3 – 41
F101
F204
F201
F203
AC Power PWB
AC Power PWB
DC Power PWB
DC Power PWB
DC Power PWB
DC Power PWB
DC Power PWB
DC Power PWB
DC Power PWB
DC Power PWB
DC Power PWB
Function/Operation
F2
F1
TS_US
TS_UM
TS LM
Section

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx-3111uMx-3110nMx-3610nMx-2010uMx-2610nMx-2310u

Table of Contents