O/RIDE Key
(Override)
The
O/RIDE
key is used to override the programmed schedule and to hold the current set
temperature indefinitely or until the
will be displayed on the LCD to confirm this function is active.
HOLD
O/RIDE Key
(Override)
The
O/RIDE
key is used as an after hours run timer for a programmed period established by the
HVAC installer (0.5 - 12 hours) or Off which will hold the override until the next scheduled event.
When the
O/RIDE
key is pressed, the LCD will display the flashing word
(occupied) temperatures will be initiated. The override can be canceled at any time by simply
pressing the
O/RIDE
Up Key ( )
This key is used to increase a desired temperature or value in programming.
Down Key ( )
This key is used to decrease a desired temperature or value in programming.
PROG Key
(Program)
This key is used to set the clock and program daily events.
PROG Key
(Program)
This key is used to set the clock and switch between
FAN Key
This key is used to select continuous fan (
Advanced Fan Function
The T-32-P has an Advanced Fan function that will run the fan continuously during occupied mode and
only run with a call for heating or cooling in the unoccupied mode. If this function has been enabled by
the installer, the fan key must be set to
the thermostat is configured for 4 schedules per day, the fan will run continuously in schedules 1, 2
and 3 and in Auto in schedule 4. If the thermostat is configured for 2 schedules per day, the fan will run
continuously in the Start mode and in Auto in the Stop mode.
Heating Call
When the T-32-P is in the
Heating
. If the word
heating call takes place.
E. Heat Call
(emergency heat)
When the T-32-P is used with a heat pump system, and the
display the word
E. Heating
Residential Programmable Mode
O/RIDE
Commercial Programmable Mode
key and the flashing word
Residential or Commercial Programmable Mode
Manual Mode
ON
Heat
mode and there is a call for heating, the LCD will display the word
Heat
flashes, this confirms that the T-32-P is initiating a time delay before the
whenever there is a call for emergency heat.
button is pressed again. The word
TIMER
will disappear on the display.
Day
and
Night
Fan ON
) or intermittent fan (
. To disable the function, simply set the fan key to
E. Heat
TIMER
and the
Start
modes.
Auto Fan
).
mode is selected, the LCD will
Auto
. If
10