Specifications

Damper Actuator Type
Communications Indicator
Damper Position Indicator
Communications
Range
Control Module Power
Control Module Housing
Control Module Dimensions
Thermostat Dimensions
TM
Application
SY ST EM
FA N

Sequence of operation

24 Volt, 10 VA, 2-wire, powered open / spring return close
Multi-color LED indicates mode of operation
Green LED indicates when damper is open
Wireless, 915MHz, proprietary protocol
Up to 100 feet
24VAC, 40VA
Molded plastic
3.25 x 5.50 x 1.125 inches (WHD)
5.00 x 4.50 x 1.00 inches (WHD)
Installation and Operation Manual
The WZ1-T is a battery powered, auto-changeover thermostat
that communicates via an RF wireless data link to a damper
control module located on the Zone One™ damper. The
system is designed to prevent overheating and overcooling of
individual zones.
Up to 8 WZ1 thermostat controlled dampers
can be used in the same location
An automatic changeover duct sensor located on the damper
senses whether there is warm air or cool air in the branch
supply duct. If the Zone One™ thermostat is calling for cooling
and the duct sensor determines there is cool air in the duct, the
damper will power open; otherwise, the damper will remain
closed. If the Zone One™ thermostat is calling for heating and
the duct sensor determines there is warm air in the duct, the
damper will power open; otherwise, the damper will remain
closed. The relay control module has LED indication to confirm
mode of operation and damper position.
Model WZ1
.

Advertisement

Table of Contents
loading

Summary of Contents for Jackson Systems WZ1

  • Page 1: Sequence Of Operation

    ZONE NE Model WZ1 Made in the USA Application The WZ1-T is a battery powered, auto-changeover thermostat SY ST EM that communicates via an RF wireless data link to a damper FA N control module located on the Zone One™ damper. The system is designed to prevent overheating and overcooling of individual zones.
  • Page 2 Wireless Zone One™ Module Installation The Wireless Zone One™ damper control module comes installed on the zone damper and is completely factory wired. The damper control module is powered by a separate 24 Volt, 40 VA transformer. DAMPER ON WHEN DAMPER ACTUATOR IS POWERED OPEN PO / SC...
  • Page 3: Removing The Subbase

    Removing the Subbase Hold the subbase with one hand, press the case as shown below and pull the bottom of the thermostat from the subbase. Press here to release case from subbase. Installing the Subbase The thermostat should be installed approximately 5 feet above the floor. Level the subbase for appearance and use the wall anchors and screws provided.
  • Page 4: Setting The Zone Number

    Setting the Zone Number If more than one WZ1 is used in the same application, each thermostat and module must be assigned a different communications address. Use the DOWN keys to set the zone number for each thermostat in the system.
  • Page 5: Programming The Module

    Cool Cooling Setpoint Limit Set To Press the NEXT key to select Option 09 and press the Down key to set the minimum allowable cooling setpoint. The minimum cooling setpoint range is 55 to 80F. Option CANCEL NEXT ENTER Programming the Module If there is only one WZ-1 installed, it is not necessary to program the address as the thermostat and damper control module default address is Zone 01.
  • Page 6: Thermostat Operation

    Thermostat Operation Up and Down keys used when adjusting temperature, time of day, Temperature Setting day of the week, and other options Space temperature Heat Set To Inside AUTO SYSTEM SYSTEM key selects Auto and Off NEXT CANCEL MENU ENTER Menu key used to set time of Fan key (Not used) day and day of week...
  • Page 7: Low Battery Indication

    Setting the Time and Weekday To set the time of day and the day of the week, press the MENU and the LCD will display the hour. Use the Down keys to set the hour. Make sure that the AM or PM is correct. Press the NEXT key to set the minute.
  • Page 8: Resetting Factory Defaults

    SYSTEM while replacing batteries Although great care has been taken in preparation of this manual, Jackson Systems takes no responsibility for errors or omissions contained herein. It is the responsibility of the installer to ensure that the Wireless Zone One™ thermostat, control module and damper are installed and wired properly to provide safe and efficient operation.

This manual is also suitable for:

Wireless zone one wz1Wireless zone one wz1

Table of Contents