Fan Speed Control; Key Lock - kozy heat CSK-25 Installation And Operation Manual

Hide thumbs Also See for CSK-25:
Table of Contents

Advertisement

9.2.8

Fan Speed Control

Fan speed can be adjusted through six (6) speeds. A single 'beep' will confirm
reception of the command. To activate this function,
1.
Press the mode key to index to the fan control icon.
2.
Press the up or down arrow keys to turn on, off, or to adjust fan speed.
Thermostat Mode: Fan(s) have a five (5) minute delay time when fireplace
is lit, allowing time for heat to build in fireplace before operating. The fan will
continue to operate for approximately twelve (12) minutes after fireplace has
been turned off.
Manual Mode: Fan(s) will operate at previous setting. There is no delay in
start up or stop time.
9.2.9
Accent Light Kit
The light intensity can be adjusted through six (6) levels. A single beep will
confirm reception of the command.
1. Press the mode key to index to light icon.
2. Press the up or down arrow keys to adjust the intensity level.
9.2.10

Key Lock

This function locks the keys to avoid unsupervised operation. A lock icon will
appear on the LCD display screen once activated.
To Activate: Press the mode key and up key at same time.
To De-activate: Press the mode key and up key at same time.
9.2.11
Low Battery Detection
Remote Control
Remote control battery lifespan depends on various factors including battery
quality, number of ignitions, changes to room thermostat set point, etc.
When the remote control batteries are low, a battery icon will appear on the
LCD display before all battery power is lost.
When batteries are replaced, this icon will disappear.
Backup Battery Pack
The backup battery pack is used when the electrical power to the appliance is interrupted. The lifespan of backup batteries
depends on various factors including battery quality, number of ignitions, changes to room thermostat set point, etc.
When backup batteries are low, a double-beep will be emitted from the IFC control module when it receives an ON/OFF
command from the remote control. This is an alert for a low battery condition of the backup batteries and after this double-beep
warning, no commands will be accepted until batteries are replaced.
When batteries are replaced, a beep will be emitted from IFC control module as soon as powered.
Figure 9.9, Accent Light Remote Operation
24
Figure 9.8, Fan Remote Operation
Figure 9.10, Key Lock Indicator
Figure 9.11, Low Battery Indicator

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chaska-25

Table of Contents