IMPORTANT INSTRUCTIONS FOR THE SAFETY.
ATTENTION
FOR THE SAFETY OF PEOPLE IT IS IMPORTANT TO FOLLOW ALL THE INSTRUCTIONS.
KEEP THESE INSTRUCTIONS WITH CARE
1° - If it is not forecast in the electric gearcase, install a switch of magnetothermic type upstream,
(omni polar with minimum port of the contacts of 3mm) with a check of conformity to the
international standards. Such devise must be protected against the accidental lockup (for
example by installing inside a locked board).
2° - For the section and the type of the cables RIB advices to use a cable of H05RN-F type with
1,5 sqmm minimum section and, however, to keep to the IEC 364 and installation standards
in force in your country.
3° - Positioning of a possible couple of photoelectric cells: the radius of the photoelectric cells
must be at a height of no more than 70cm from the ground and at a distance not superior to
20 cm from the motion plane of the door. Their correct working must be verified at the end of
the installation in accordance with point 7.2.1 of the EN 12445.
4° - To fulfil the limits set by EN 12453, and in case the peak force exceeds the normative limit of
400 N it is necessary to have recourse to the active presence survey on the whole height of
the door (up to max 2,5m). - The photoelectric cells, in this case, must be applied in
accordance with the point 7.3.2.2 of the EN 12445.
5° - Verify monthly that the movement motor goes into reverse when the door touches a 50 mm
high object set on the floor. If necessary, adjust and verify again, since an incorrect
adjustment can be a danger.
N.B.: The earthing of the system is obligatory.
The data described in this handbook are purely a guide.
RIB reserves the right to change them in any moment.
Carry out the system in the respect of the standards and laws in force.
TECHNICAL
CHARACTERISTICS
Max surface door
Max height door
Max Force
Opening Time
Feeding and Frequency CEE
Maximum power absorption
Maximum current absorption
Feeding and Frequency CEE
Maximum power absorption
Maximum current absorption
No. normative cycles 230V/120V
No. of daily operations suggested
Service
No. guaranteed consecutive cycles
Max weight
Noise
Work Temperature
Protection degree
*COMET 60 S can opens a door height up to 3,4mt adding the optional extension
accessory code ACG8202.
Pay attention to the "OVER" card and check:
- if JP2 is closed, the card is for the motor COMET 60S depicted
- if JP2 is open, the card is for the motor COMET 80S depicted
Please, refer to the section "Electrical Links".
PRE-INSTALLATION CHECK
N.B. It is obligatory to uniform the characteristics of the door to the standards
and laws in force. The door can be automatized only if in a good state and if in
accordance with EN 12604 standard.
- The door must not have pedestrian doors. Contrariwise, it will be necessary to
take the appropriate precautions in accordance with the point 5.4.1 of
EN12453 (for example stop the motion of the motor when the door is open,
thanks to a micro switch conveniently connected in the gearcase)
- No trapping points must be generated (for example between horizontally
pivoted open door and wall).
COMET
60 S
80 S
m
2
5
7
m
2,4 (3,4*)
3,4
N
700
900
s
20
25
230V ~ 50/60Hz
W
180
170
A
0,6
0,5
120V ~ 60Hz
W
98
82
A
0,82
0,68
4 - 20s/2s
4 - 25s/2s
30
30%
7/20s
13/25s
Kg
16,5
19
db
<70
°C
0 ÷ +55°C
IP
20
IMPORTANT SAFETY INSTRUCTIONS FOR THE INSTALLATION
ATTENTION - THE INCORRECT INSTALLATION CAN CAUSE SERIOUS DAMAGES
FOLLOW ALL INSTALLATION INSTRUCTIONS
1° - This handbook is exclusively addressed to the specialized personnel who knows the
constructive criteria and the protection devices against the accidents for motorized gates,
doors and main doors (follow the standards and the laws in force).
2° - The installer will have to issue a handbook to the final user in accordance with the 12635.
3° - The installer will have to put the tags warning against the entrapping dangers near the
controls and the horizontally pivoted door.
4° - Check frequently the system, in particular cables, springs and supports to find out possible
unbalances, wear signs or damages. The final user must not operate electrically the
horizontally pivoted door if this needs maintenance or repair, since a failure in the installation
or a non correctly balanced barrier can provoke wounds.
5° - Before proceeding with the installation, the installer must forecast the risks analysis of the
final automatized closing and the and the safety of the identified dangerous points (Following
the standards EN 12453/EN 12445).
6° - Before proceeding with the installation, the installer must remove superfluous cables or
chains and disable any unnecessary device after the installation of the motion motor.
7° - Before installing the motion motor, the installer must verify that the door is in good
mechanical conditions and that it adequately opens and closes.
8° - The installer must install the member for the manual release at a height inferior to 1,8m.
9° - The installer will have to remove possible impediments to the motorized motion of the door
(eg. Door bolts, sliding bolts, door locks etc.)
10° - The installer will permanently have to put the tags warning against the deflection on a very
visible point or near possible fixed controls.
11° - The wiring harness of the different electric components external to the operator (for example
photoelectric cells, flashlights etc.) must be carried out according to the EN 60204-1 and the
modifications to it done in the point 5.2.2 of the EN 12453.
12° - The possible assembly of a keyboard for the manual control of the movement must be done
by positioning the keyboard so that the person operating it does not find himself in a
dangerous position; moreover, the risk of accidental activation of the buttons must be
reduced.
13° - Keep the automatism controls (push-button panel, remote control etc.) out of the children
way. The controls must be placed at a minimum height of 1,5mt from the ground and
outside the range of the mobile parts.
14° - Before carrying out any installation, regulation or maintenance operation of the system, take
off the voltage by operating on the special magnetothermic switch connected upstream.
15° - At the end of the installation, the installer will have to make sure that the parts of the door do
not encumber streets or public sidewalks.
16° - At the end of the installation, the installer will have to make sure that the motion motor
prevents or blocks the opening motion when the door is loaded with a 20 Kg weight, fixed in
the middle of the inferior edge of the door (for doors with openings of width superior to
50mm diameter)
17° - At the end of the installation, the installer will have to make sure that the mechanism is
correctly regulated and that the motion motor goes into reverse when the door touches a
50mm high object set on the floor.
THE RIB COMPANY DOES NOT ACCEPT ANY RESPONSIBILITY for possible damages
caused by the non observance during the installation of the safety standards and of the laws in
force at present.
OPERATOR TECHNICAL CHARACTERISTICS
COMET S is a patented, non-reversible operator utilizable to move horizontally pivoted doors and
balanced with springs sectionals (Fig. 1).
It is equipped with a motor with an incorporate encoder, an electronic board with radio receiver, a
manual unlock in case of voltage lack, with a light, a guide with a chain, trolley, adjustable flasks,
small blocks for the fastening.
It is possible to purchase a door pulling arm that can be used for spring balanced sectional and
up and over garage doors (code ACG8203), or a special adaptor for counterweighted up and
over garage door (code ACG8201).
Parts to install meeting the EN 12453 standard
COMMAND TYPE
with manned operation
with visible impulses (e.g. sensor)
with not visible impulses
(e.g. remote control device)
automatic
* a typical example are those shutters which do not have access to any public way
A: Control push button with a person present (i.e. with constant action), as cod. ACG2020
B: Key selector with a person present, as cod. ACG1010
C: Incorporated encoder (with function of couple limiter)
D: Encoder incorporated (with function of presence detector)
USE OF THE SHUTTER
Skilled persons
Skilled persons
(out of a public area*)
(public area)
A
B
C
C
C
C and D
C and D
C and D