4. External interfaces
Example of GPI Out and ALARM connections
Ensure that the conditions given below are satisfied.
Dielectric strength: Max. DC 24 V
Current:
Max. 50 mA
AV-HS410
GPI Out
ALARM Out
(Max. current: 50 mA)
Com
TALLY/GPI 1
8
7
6
5
15
14
13
12
Pin No.
1
GPI-Out1
9
GPI-Out9
2
GPI-Out2
10
ALARM Out
3
GPI-Out3
11
GPI-In1
4
GPI-Out4
12
GPI-In2
5
GPI-Out5
13
GPI-In3
6
GPI-Out6
14
GPI-In4
7
GPI-Out7
15
GPI-Com
8
GPI-Out8
(Max. voltage: 24 V)
Tally LED
TALLY/GPI 2
4
3
2
1
11
10
9
Signal name
Example of GPI In connections
Provide contact inputs.
AV-HS410
+3.3 V
8
7
6
5
4
3
2
15
14
13
12
11
10
Pin No.
Signal name
1
GPI-Out10
9
GPI-Out18
2
GPI-Out11
10
GPI-Out19
3
GPI-Out12
11
GPI-In5
4
GPI-Out13
12
GPI-In6
5
GPI-Out14
13
GPI-In7
6
GPI-Out15
14
GPI-In8
7
GPI-Out16
15
GPI-Com
8
GPI-Out17
113
GPI In
Com
1
9

Advertisement