Harris ENC6800+ Installation And Operation Manual page 63

Table of Contents

Advertisement

Note
The same type of genlock
format (NTSC, PAL-M, or
PAL-B) should never be applied
to both genlock input sources at
the same time.
Note
Bent pins may also cause
communications issues with
Pilot Lite, Pilot or Navigator.
ENC/ENS6800+ Installation and Operation Manual
source. Remember that the jumper determines whether
Genlock 1 or the Frame is the source of the second genlock
input (see
Figure B-1 on page
When the genlock input is valid, the D7 Genlock LED on the card
edge will turn green.
2. (ENS6800+ only) Check that the Frame Sync Mode parameter is
set to Sync mode. If this parameter is set to Delay, it will not
synchronize the video to the genlock reference.
3. Check that the Genlock Mode parameter is not set to Free Run
mode. If this parameter is set to Free Run, the video will not
synchronize to the genlock reference.
4. Check that the SDI Video Standard parameter is set to the correct
standard for the current video input. This parameter is normally left
in Auto mode where it will automatically switch between 525 and
625 SDI video standards as the input changes. However if this is
forced into 525 or 625, then the genlock input must match the
chosen standard. For example, if 625 mode is selected but an NTSC
reference is present on the genlock input, the unit will not genlock
or synchronize.
5. If the first four items are correct on your module, the next thing to
check is the back module. Follow these steps:
a. Unplug the front module.
b. Unscrew and remove the back module.
Appendix B: ENC/ENS6800+ Troubleshooting
48).
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ens6800+

Table of Contents