Information Windows - Kingspan SC100 Installation And Operating Instructions Manual

Temperature difference controller
Table of Contents

Advertisement

10

Information windows

The following information windows are displayed whenever a function's settings are not complete, activa-
tion of a function is not possible, errors occur in the system, or certain functions are currently activated.
Display
44
Description
Function cannot be activated as the cor-
responding settings are incomplete.
Function was deactivated again.
Function cannot be activated, as all
outputs are already occupied.
When changing systems, all settings of
functions and parameters are reset.
It is not possible to access storage prior-
ity, as the selected system only has one
storage tank.
In order to protect the pumps from me-
chanical seizure, all pumps are switched
on briefly once a day.
The holiday function is activated.
Storage tank is being recooled by the
system.
System is conducting hygiene-flushing
of the circulation pipe.
"Stagnation reduction" is activated.
System is operating at high temperature
level.
The solar circuit has stopped because
the controller is conducting a priority
test. This test checks whether, instead
of the second-priority storage tank, the
first-priority storage tank could also be
loaded.
This test can take several minutes, as the
collector array must heat up sufficiently.
Solar circuit is running due to interval
test.
The collector's heat transfer fluid is be-
ing transported to the sensor.
EN
Measures
Check and complete the settings.
If the selected layout, or another
function, is to be retained, this func-
tion cannot be used.
Settings which are still needed, and
which must be configured anew,
must be noted down in advance.
The setting is not required with this
system.