Display: .1
Display: .1
[Circulation]
[Circulation]
[.................]
[.................]
Display: .1.3
Display: .1.3
[Temp. controlled]
[Temp. controlled]
T
T
?
?
[...]: 30°C
[...]: 30°C
[...]: 35°C
[...]: 35°C
Display: .1.3.1
Display: .1.3.1
[on]
[on]
[off]
[off]
EN
NOTE
R? or T? indicates an output or input which has not yet been selected.
Only outputs which are not yet required by the respective system can be
selected. Double allocation of outputs is not possible. However, double
allocation of inputs is possible. This is also displayed in an information
window (see chapter 10).
Leaving the menu
ESC: press button.
 
7.2.2
Circulation function
A circulation pump can be controlled in a temperature-based or pulse-
based manner. These types of control can also be combined with each
other.
Temperature control: when the temperature in the circulation return
falls below the "on" value, then the pump is switched on until the "off"
temperature is reached.
NOTE
In order to avoid measurement errors caused by the pipe's thermal con-
duction, a minimum clearance space of 1.50 m from the storage tank
should be observed when installing the circulation sensor.
Pulse control: when the circulation function is requested via a pulse
(e.g. from a flow switch), the pump runs for the set circulation duration.
Subsequently, no further requests are accepted until the set wait time
has expired.
Activating temperature control
"Functions" submenu selected, see "Selecting a function"
(chapter 7.2.1).
Circulation activated, see "Activating a function" (chapter 7.2.1).
Outputs selected, see "Selecting an output" (chapter 7.2.1).
: press button.
The "Temp. controlled" display appears.
SET: press button.
 
Temperature control is activated.
: press button.
The display for setting the temperature input and the "on" and
"off" values appears.
SET: press button.
"T" flashes in the display (circulation pipe temperature input).
: choose the desired input.
SET: press button to confirm.
The "on" value flashes after confirmation of the temperature
sensor.
: set the "on" value.
SET: press button to confirm.
 
The "off" value flashes after confirmation of the "on" value.
: set the "off" value.
SET: press to confirm and close.
The settings are saved.