Activating pulse control
"Functions" submenu selected, see "Selecting a function"
(chapter 7.2.1).
Circulation activated, see "Activating a function" (chapter 7.2.1).
Outputs selected, see "Selecting an output" (chapter 7.2.1).
: press button.
The "Pulse controlled" display appears.
SET: press button.
Pulse control is activated.
: press button.
The display for setting the pulse input, circulation time, and wait
time appears.
SET: press button.
Pulse input flashes.
: choose the desired output.
SET: press button to confirm.
The circulation duration flashes after confirmation of the input.
: set the circulation duration.
SET: press button to confirm.
The wait time flashes after confirmation of the circulation dura-
tion.
: set the wait time.
SET: press button to confirm the wait time and close.
The settings are saved.
ESC: leave the "Circulation" submenu.
7.2.3
Back-up heating function
This function allows thermostatic control of an output for additional
heating of the solar storage tank using an oil or gas burner.
Temperature control: When the temperature in the upper part of the
storage tank falls below the "on" value, then the output is switched on
until the "off" temperature is reached.
Choosing the input and setting the temperature limits
"Functions" submenu selected, see "Selecting a function"
(chapter 7.2.1).
Back-up heating activated, see "Activating a function" (chapter 7.2.1).
Outputs selected, see "Selecting an output" (chapter 7.2.1).
: press button.
The display for setting the temperature input and the "on" and
"off" values appears.
SET: press button.
"T" flashes in the display (storage tank temperature input).
: choose the desired output.
SET: press button to confirm.
The "on" value flashes in the display.
: set the "on" value.
SET: press button to confirm.
The "off" value flashes after confirmation of the "on" value.
: set the "off" value.
SET: press button to confirm.
The settings are saved.
6
EN
 
Display: .1.4
Display: .1.4
[Pulse controlled]
[Pulse controlled]
 
Input: ?
Input: ?
Circulation:  min
Circulation:  min
Wait time:
Wait time:
Display: .1.4.1
Display: .1.4.1
 
[.................]
[.................]
Display: .
Display: .
[Back-up heating]
[Back-up heating]
 
Display: ..3
Display: ..3
[on]
[on]
[off]
[off]
78.138 | 08.1
[................]
[................]
10 min
10 min
T
T
?
?
[...]: 55°C
[...]: 55°C
[...]: 60°C
[...]: 60°C