7.3.2
Setting the loading strategy parameter
Access the "loading strategy" parameters, (see chapter 7.3.1).
✓
SET: press button.
The display for setting the temperature differential control or
target temperature control appears.
Choosing loading strategy between temperature dif-
ferential control and target temperature control
SET: press button for approx. sec.
Select either temperature differential control (dT) or target tem-
perature control (T).
Setting the temperature differential value or target
temperature value
SET: press button.
The temperature differential value flashes in the display (e.g.
dT=8 K).
: set the temperature differential value.
SET: press button to confirm.
The target temperature value flashes in the display (e.g.
T=60 °C).
: set the target temperature value.
SET: press button to confirm.
The settings are saved.
7.3.3
Setting the RPM control parameter
Access the "RPM control" parameter, (see chapter 7.31).
✓
SET: press button.
The display for activating (yes) or deactivating (no) the RPM
control is shown.
Activating or deactivating the RPM control
SET: press button for approx. sec.
Choose between "yes" and "no" for RPM control.
Setting the minimum speed
SET: press button.
The min. RPM value flashes.
: set the minimum speed.
SET: press button to confirm.
The settings are saved.
36
EN
[.........
[.........
.............
.............
............]
............]
Display: 3.1
Display: 3.1
[loading
[loading
strategy
strategy
of storage tank 1]
of storage tank 1]
Display: 3.1 Settings window
Display: 3.1 Settings window
[.........
[.........
.............
.............
............]
............]
Display: 3.4
Display: 3.4
[RPM
[RPM
control
control
pump R1]
pump R1]
Display: 3.4 Settings window
Display: 3.4 Settings window
[no]
[no]
[yes]
[yes]
78.138 | 08.1
8 K
8 K
ja
ja
[...]
[...]
[...]
[...]
(min 50%)
(min 50%)