In the event of an error, the system status light displays diagnostic indications. Errors are encoded as follows: one
(for a low battery voltage fault) to twelve (module mismatch) and are displayed by the light flashing the number of
times prescribed by the error code. The flash sequence (one to twelve) is followed by a long off period (2 sec-
onds). If more than one error exists, then the error having the highest priority is indicated. The controller must be
turned off and then on again even if the source of the error is removed. If you cannot resolve the problem, contact
your authorised Pride Provider.
Flash Code Sequence
•—•—•—
••—••—••—
•••—•••—
••••—••••—
•••••—•••••—
••••••—••••••—
•••••••—•••••••—
•••••••—•••••••—
•••••••—•••••••—
•••••••—•••••••—
•••••••—•••••••—
•••••••—•••••••—
36
V I I .
O P E R A T I O N
Diagnosis
DX module fault
DX accessory fault
Left motor (or connection) fault
Right motor (or connection) fault
Left park brake fault
Right park brake fault
Low battery fault
Over voltage fault
CANL fault
CANA fault
Stall timeout
Module mismatch
www.pridemobility.com
Solution
See your authorised Pride Provider.
See your authorised Pride Provider.
Check left motor wiring.
Check right motor wiring.
Check motor/brake wiring.
Check motor/brake wiring.
Check that the battery wiring is secure.
Check that the battery wiring is secure.
See your authorised Pride Provider.
See your authorised Pride Provider.
Turn unit on, then off.