I I I .
The Power Base Assembly
The power base assembly consists of the right and left frame assemblies, the front and rear battery boxes, and the
electronics tray. See figures 5, 6, and 7.
Ammeter: The ammeter displays the charger's current output in amps. See VIII. "Batteries and Charging."
Charger Power Cord Receptacle: This is where the charger power cord plugs into the onboard charger. The
charger power cord also plugs into a standard wall outlet.
Charger Fuse(s): The charger fuse protects the ammeter from overload during charging. The charger fuse is
located under the electronics tray. A spare fuse is included.
Main Circuit Breaker: The main circuit breaker is a safety feature built into your power chair. When the batteries
and the motors are heavily strained (e.g., from excessive loads), the main circuit breaker trips to prevent damage
to the motors and the electronics. If the circuit breaker trips, allow your power chair to "rest" for approximately
one minute. Then push in the circuit breaker reset button, turn on the controller, and continue normal operation. If
the main circuit breaker trips repeatedly, contact your authorised Pride Provider.
Controller Connector: This is where the controller connects to the battery, the motors, and the motor brakes.
The VSI controller connector is shown.
Charger Inhibit Connector (VSI only): The VSI controller is equipped with a charger inhibit. The charger
inhibit enables the onboard battery charger to disable the controller during charging. The charger inhibit connector
is coded with colored dots. The dots are positioned so that you can align the flat side of the male connector with the
flat side of the female connector before making the connection.
WARNING! Failure to properly align the connectors can result in damage to the controller,
the onboard charger, and the connectors.
Manual Freewheel Levers
For your convenience, your power chair is equipped with two manual freewheel levers - one for each motor/brake
assembly. See figures 8 and 9. These levers allow you to disengage the drive motors and maneuver the chair
manually.
WARNING! Do not use your power chair while the drive motors are disengaged unless you
are in the presence of an attendant! Do not disengage the drive motors when your power
chair is on an incline. The chair could roll down on its own, causing injury!
To engage or disengage the drive motors:
1. Turn the freewheel levers outward to disengage the drive motors.
2. Turn the freewheel levers toward the front of the power chair to engage the drive motors.
WARNING! Remember that when your power chair is in freewheel mode, the electronic
braking system is disengaged.