H*38DF PRC Panorama Indoor Gas Fireplace
Section:
Acceptable vent run
within non-shaded area.
B
59"
18 "
Figure 13. HP38PR* Top Vent Venting Graph for wall mounted terminations.
Flex or Rigid
Section
Hearth
Figure 13a. HP38PR* Top Vented, wall mounted installation with one 90°
bend. The vent run must comply with Venting Graph for Top vent, wall
mounted terminations, Figure 12a.
Page 14
Installation
A
C
Unacceptable vent run
within shaded area.
If your installation does not fall with
in the venting graph parameters,
please contact a local Montigo
dealer for Power Venting options.
.
.
18" Max.
Heat
Shield
Termination
59"
Min.
Exterior
Wall
150"max.
Figure 13b. H38PR*, HL38PR*, or HP3PR* Top Vented, wall mounted
Multi-elbow installation. See Venting Graph for Top vent, wall mounted
terminations, Figure 12 or 12a.
126" Max.
30" Max.
Flex
Section
Figure 13c. H38PR* , HL38PR* or HP38PR* Top Vented, wall mounted
Retracted Multi-elbow installation. See Venting Graph for Top vent, wall
mounted terminations, Figure 12 or 12a.
Note: Images are shown without screens for clarity purposes.
However, your fireplace should not be operated without proper
installation of screens.
Heat
Shield
Termination
Solid
Section
Flex
Section
Exterior
Wall
Hearth
Heat
Shield
Termination
Solid
Section
Exterior
Wall
Hearth
XG0211 - 151126