Montigo H38DF-PRC Installation, Operation & Maintenance Manual

Indoor panorama gas fireplace

Advertisement

H38DF-PRC Gas Fireplace
HL38DF-PRC Shown
Warning:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional
information consult a qualified installer, service agency or the gas supplier.

Safety Notice:

Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain
hot even after the fireplace has been turned off. Safety screens are available and
can reduce the risks of severe burns. Please keep children away from the fireplace
at all times.

For Your Safety:

Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
XG0211
Canadian Heating Products Inc. Langley, BC V4W 4A
Installation Operation & Maintenance Manual
Check local codes and read all instructions prior to installation.
®
C
US
www.montigo.com
H38DF-PRC
HL38DF-PRC
HS38DF-PRC
HLS38DF-PRC
Warning:
mation in these instructions is not
followed exactly, a fire or explosion
may result causing property dam-
age, personal injury or death.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical
switch; do not use any phone in
your building.
Immediately call your gas
supplier from a neighbor's
phone. Follow the gas supplier's
instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Montigo Del Ray Corp. Ferndale, WA 98248
If the infor-
Installer: Leave this manual
with the appliance.
Consumer: Retain this
manual for future reference.
080510

Advertisement

Table of Contents
loading

Summary of Contents for Montigo H38DF-PRC

  • Page 1: Safety Notice

    • Installer: Leave this manual with the appliance. • Consumer: Retain this ® manual for future reference. XG0211 Canadian Heating Products Inc. Langley, BC V4W 4A Montigo Del Ray Corp. Ferndale, WA 98248 080510...
  • Page 2: Table Of Contents

    Section 8: Installing the Accessories Standard Top Vent (no elbows or offsets)..... ▪ ......19 Installing the H38DF-PRC Log Set Top Vent (two elbows one offset) ......▪ ...... 20 Installing the HL38DF-PRC Firestones Top Vent (multi-elbows and offsets) .....
  • Page 3: Safety Alert Key

    Warranty and Installation Information : (See Appendix B) Congratulations on your purchase of a Montigo Fireplace. The Montigo warranty will be voided by, and Montigo disclaims any With over 30 years of experience, Montigo is committed to providing responsibility for, the following actions: you with a gas fireplace that is not only a beautiful addition to your ►...
  • Page 4: Installation

    Should it be impossible to meet the venting requirements laid „ out in Section 3: Venting, please contact Montigo regarding the BEFORE YOU START: use of a Montigo Power Vent. Lay out the Vent run; calculating the required elbows and straight „...
  • Page 5: Installation Overview And Product Dimensions

    H(L)38DF-PRC Indoor Panorama Gas Fireplace Installation Section 1: Installation Overview and Product Dimensions Please review the Pre-Installation Checklist on Page 4 for general information on preparing for a successful installation of your fireplace. The H*38PR* fireplace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing. Safety, as well as efficiency of operation, should be considered when selecting the fireplace location.
  • Page 6: Framing The Fireplace

    H(L)38DF-PRC Indoor Panorama Gas Fireplace Installation Section 2: Framing Installing The Standoffs Frame in the enclosure for the unit with framing materials. The framed opening for the assembled fireplace is 40 7/8" wide, x 44" To avoid elevated mantel temperatures, all H*38PR* gas high x 24 5/8"...
  • Page 7: The Direct Vent System

    Installation Section 3: Venting Montigo supplies a variety of direct venting and termination options. 4. Install the (5" and 8") collars to the rear vent outlet using the The direct vent termination location MUST be selected such that included hardware, as illustrated Figure 8.
  • Page 8: Section 3-2: Installing A Roof Mounted Termination

    H(L)38DF-PRC Indoor Panorama Gas Fireplace Installation Section 3-2: INSTALLING A ROOF MOUNTED DIRECT VENT PVTK1 TERMINATION (PVTK-1) Termination This section applies to installations where the direct vent termi- 2’ min. nation will be roof mounted. Section 3-2-1: SuQQort ring VENTING LAYOUT Selection of components and details of venting lay out should SuQQort Qlate 32’...
  • Page 9: Section 3-2-2: Venting Components

    „ outer and inner pipes to keep the pipes separate and avoid any possible hot spots. Montigo recommends the use of a flex section for the final pipe „ connected directly to the fireplace offering greater flexibility of installation and absorption of movement.
  • Page 10: Section 3-3: Installing A Wall Mounted Termination

    H(L)38DF-PRC Indoor Panorama Gas Fireplace Installation Section 3-3: INSTALLING A WALL MOUNTED DIRECT VENT 4). Installation of termination from inside structure TERMINATION A Termination with a MOSR Frame is installed from the inside of the This section applies to installations where the direct vent termi- structure.
  • Page 11: Section 3-3-1: Venting Layout

    All through-the-wall terminations beyond 3' of the fireplace must „ If your installation does not fall 42” have a Montigo Heat Shield (RHS8) installed. See Section 3-3-3. within the venting graph para- meters, please contact Montigo Once the proposed venting layout has been determined refer to „...
  • Page 12 If your installation does not fall Graph for Rear vent, wall mounted terminations, Figure within the venting graph para- meters, please contact Montigo for Power Venting options. NOTE: This configuration is available to ALL installations of Rear vent, Wall Terminations except straight through the wall installations, as shown in figure 16a.
  • Page 13 „ and inner pipes to keep the pipes separate and avoid any possible hot spots. Montigo recommends the use of a flex section for the final pipe „ connected directly to the fireplace offering greater flexibility of installation and absorption of movement.
  • Page 14: Section 3-3-3: Heat Shields

    H(L)38DF-PRC Indoor Panorama Gas Fireplace Installation Section 3-3-3: Heat Shields Installing a Wall Mounted RHS101 Heat shield. The RHS101 Heat shield MUST be used where the RHS8 Termination (Figure 19 and 19a) CANNOT be used. Use the RHS101 where any Installing a Wall Mounted RHS8 Heat shield of the dimensions are within the parameters shown, figure 19a.
  • Page 15: Wiring

    H(L)38DF-PRC Indoor Panorama Gas Fireplace Installation Installation Section 4: Wiring Honeywell (Q3450) Pilot Assembly Pilot Electrical Harness Connector Honeywell Gas Control (SV9501M) Gas Control Connector Junction Box Fan Plug ReceQtacle Models Included Black H38PRNE 115VAC White H38PRLE 24VAC Green Gnd Screw 40 VA Transformer Wall Switch...
  • Page 16: Installing The Gas Line

    To check pressures, control valves have a provision to remove „ a 1/8” N.PT. plug to be fitted with a hose barb. Montigo requires a service shut off valve be located in an „ accessible location to isolate the gas supply.
  • Page 17: Finishing

    H(L)38DF-PRC Indoor Panorama Gas Fireplace Installation Installation Section 6: Finishing Finishing Around the Fireplace Combustible mantels and mouldings may be safely installed over the top and on the front of the fireplace provided that they do not project beyond shaded area shown in Figure 24. Fireplace Facing When sizing the finish material for your fireplace, it is important to remem- ber the following: THE OPENING MUST NOT BE OBSTRUCTED IN ANY...
  • Page 18: Installing And Removing The Door

    H(L)38DF-PRC Indoor Panorama Gas Fireplace Installation Installation Section 7: Installing & Removing the Door Removing the door: The H*38PR* doors are removed in a few simple steps. Follow these Step 5: below to remove the Horizontal access panel, unlatch the door buckles Ensure the tool is firmly and, remove the door.
  • Page 19: Installing The H38Df-Prc Log Set

    H(L)38DF-PRC Indoor Panorama Gas Fireplace Installation Installation Section 8: Installing the Log Set Bottom Logs The H*38PR* is supplied with eight (8) fibre logs. The two small bottom logs ("A" ) are mounted on the burner grate by placing them Log C diagonally onto the supplied Log stands.
  • Page 20 Optional River Rocks The H*38PR* has the option of installing the cultured rocks which mimic real stone. These may be spaced at random, or in a visual pattern of your preference. See the Montigo web site for photographs and ideas. www.montigo.com Figure 28b.
  • Page 21: Lighting Instructions

    H(L)38DF-PRC Indoor Panorama Gas Fireplace Operation Installation Section 9: Start-up Sequence with Continuous Pilot with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING! If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 22 H(L)38DF-PRC Indoor Panorama Gas Fireplace Operation Installation with Honeywell Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING! If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. If you cannot reach your gas supplier, call the Fire A.
  • Page 23 H(L)38DF-PRC Indoor Panorama Gas Fireplace Operation Installation Proflame SIT Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING! If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A.
  • Page 24: Maintenance

    H(L)38DF-PRC Indoor Panorama Gas Fireplace Maintenance Lighting Instructions General See pages 21 to 23 Have the fireplace and installation inspected yearly. The inspection „ must include, but is not limited to, the following: Burner Adjustment • A visual check of the entire vent system and termination. •...
  • Page 25: Gas Control Valve

    H(L)38DF-PRC Indoor Panorama Gas Fireplace Maintenance Troubleshooting Gas Control Valve Power Generator Pilot Adjustment Screw Wall Switch Inlet Pressure Manifold Pressure Test Connection Figure 33. Sit Nova 820 gas valve. Pilot Burner Adjustment 1. Locate Pilot Adjustment Screw. (See figure 33.) 2.
  • Page 26: Termination Locations

    H(L)38DF-PRC Indoor Panorama Gas Fireplace Appendix A - Termination Locations A = clearance to the termination frame above grade, veranda, porch, deck, clearance above paved sidewalk or a paved driveway located on public † or balcony [16 inches (41 cm) minimum] property [*7 feet (2.1 m) minimum] B = clearance to door, or sides and top of window, that may be opened [16 P = c l e a r a n c e u n d e r v e r a n d a , p o r c h , d e c k , o r b a l c o n y...
  • Page 27: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 28: State Of Massachusetts

    H(L)38DF-PRC Indoor Panorama Gas Fireplace Appendix C - State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by...
  • Page 29 H(L)38DF-PRC Indoor Panorama Gas Fireplace Notes Part No. XG0211 - 080510 Page 29...
  • Page 30 XG0211 - 080510 Montigo Del Ray Corp. Canadian Heating Products Inc. Ferndale, WA 98248 Langley, BC V4W 4A1...

Table of Contents