Power Connection

This camera is compatible with 24vAC and Power over Ethernet (PoE+). Connect power to the
camera using the provided power connector lead, or the terminal connector blocks. If you are
connecting 24vAC power, verify the polarity of the power connection. If you are using PoE+,
make sure the Power Sourcing Equipment (PSE) is in use in the Network.
The 'notches' on the left side of the graphic above correspond to notches in the green plastic
Note
of the power connector.
1. Connect POSITIVE 24 volt AC power to pin 1.
2. Connect ground wire to pin 2.
3. Connect NEGATIVE 24 volt AC power to pin 3.
Be careful not to pull the cables improperly during installation. Toshiba suggests that you
Note
fasten the cables after installation is complete.

Grounding Recommendation

The GND (ground) wire must be directly connected to the middle pin of the 24vAC power
connector. Failure to connect the ground can cause damage and failure of the camera and may
void the warranty.

Ethernet Cable Connection

Connect one end of the CAT 5 Ethernet cable to the RJ-45 connector of the camera and the other
end of the cable to the network switch or recorder.
If you are connecting the camera directly to a recorder, a crossover cable is necessary for
Note
most configuration.
Check the status of the link indicator and activity indicator LEDs. If the LEDs are unlit, check the
LAN connection.
20
The Orange activity light flashes to indicate network activity.
The Green link light indicates a good network connection.