MESSAGES AND ALARMS

Flow meter
Gr. X
Time-out alarm
Boiler filling up
Probe unconnect
Service
999999999
Change filter
999999999
If boiler filling time exceeds the programmed time (2 minutes), all of the Drink buttons lights will
flash and the machine will be disabled. To re-enable it, turn the machine off and on again at the power
switch.
If the electronic control panel does not receive a pulse from the flow meter (coffee too fine or flow
meter fault) within 5 seconds of pressing one of the espresso buttons, the light for the dose selected
will start to flash. To disable it, press the dose button again.
As an additional safety, all dose settings have a maximum dispensing time of 5 minutes.
Fault in flow meter X
Flow fault detected in counter X
Check that the machine is receiving water.
Temperature sensor fault
Service the machine.
To disable the alarm and reset the counter:
Turn off the machine. Simultaneously press and hold down
the 1 Short Espresso
buttons. Turn on the machine.
Regenerate the filter.
To disable the alarm and reset the counter:
Turn off the machine. Simultaneously press and hold down the 2
Short Espressos
and 2 Long Espressos
on the machine.
Rosetta Capsule Group
and 1 Long Espresso
buttons. Turn
31