(20) Command "WID"
Function: Command for writing camera ID (set by user) (Write ID)
Transmission from host: STX: "WID": character string of up to 15 characters: ETX
Return by camera:
The acceptable characters are English 1 byte characters (both upper and lower cases) and some special symbols as
shown below:
Usable special symbols······ SP(H'20), !(H'21), '(H'27), +(H'2B), comma (H'2C), -(H'2D), .(a full stop mark)(H'2E),
(Note) When the number of the characters exceeds 15, (transaction rejection) is returned.
(Note) When the number of the characters is 0, the ID code is deleted.
(Note) Carefully note that ID is not correctly written when the character string to be sent includes an unusable character(s).
This case, however, is not regarded as error ((transaction rejection) is not returned).
(Note) This command does not execute the writing into EEPROM and therefore, the setting by this command is lost when
the power is turned off. If it is necessary to store the setting in EEPROM, transmit another command of "SID".
(21) Command "SID"
Function: Command for saving camera ID (set by user) (Save ID)
Transmission from host: STX: "SID": ETX
Return by camera:
The data of the current ID code can be saved in EEPROM.
(Note) The ID code (character string) is saved in an area independent from the program pages, and this common value
(one numerical number) is applied when the camera is turned on with any one of the program pages.
(Note) No ID code is stored before shipment.
(22) Command "RID"
Function: Command for reading out camera ID (set by user) (Read ID)
Transmission from host: STX: "RID": ETX
Return by camera:
The data (up to 15 characters) of the ID code (character string) is read out. When an ID code is not set, the number of the
characters to be returned is 0.
(23) Command "WVSUB"
Function: Command for writing Vsub value (CCD substrate voltage) (Write VSUB)
Transmission from host: STX: "WVSUB": Vsub set value: ETX
Return by camera:
(24) Command "SVSUB"
Function: Command for saving Vsub value (CCD substrate voltage) (Save VSUB)
Transmission from host: STX: "SVSUB": ETX
Return by camera:
(25) Command "RVSUB"
Function: Command for reading out Vsub value (CCD substrate voltage) (Read VSUB)
Transmission from host: STX: "RVSUB": ETX
Return by camera:
(26) Command "RMG"
Function: Command for reading MGC gain (Read MGC GAIN)
Transmission from host: STX: "RMG": ETX
Return by camera:
STX: ACK: ETX (transaction completion), or STX: NAK: ETX (transaction rejection)
/(H'2F), : (H'3A), ;(H'3B), <(H'3C), =(H'3D), >(H'3E), ?(H'3F), [(H'5B)], (H'5D), _ (H'5F)
STX: ACK: ETX (transaction completion), or STX: NAK: ETX (transaction rejection)
STX: ACK: "RID": character string of up to 15 characters: ETX (transaction completion), or STX:
NAK: ETX (transaction rejection)
STX: ACK: ETX (transaction completion), or STX: NAK: ETX (transaction rejection)
STX: ACK: ETX (transaction completion), or STX: NAK: ETX (transaction rejection)
STX: ACK: "RVSUB": Vsub set value: ETX (transaction completion),
or STX: NAK: ETX (transaction rejection)
STX: ACK: "RMG": MGC setting value: MGCB setting (right screen): ETX