GigE FC11000GE Instruction Manual page 21

11 megapixel progressive scan monochrome/color camera
Table of Contents

Advertisement

(6-7)
Typical setting procedure
START
Turn on power.
Set mode switch to "5".
Apply upward stroke to UP/DOWN
switch.
Set shutter switch to "4".
Set mode switch to "0".
Set gain by manipulating UP/DOWN
switch upward or downward.
Change mode switch to "5".
Apply downward stroke to UP/DOWN
switch.
Set mode switch to "A".
Apply upward stroke to UP/DOWN
switch.
Turn off power.
END
Fig. 6-3 Example of procedure for gain setting for asynchronous shutter
(Note) This equipment is put into the condition where the cyclic asynchronous shutter trigger is internally generated (in the
cyclic trigger state) when the menu is displayed. Therefore, when the menu is displayed, it is not necessary to
temporarily switch to the continuous shutter operation as shown above.
(6-8) Read out of factory default
Setting items to be read out to RAM
[Electronic shutter operation mode]
• Shutter mode
• Type of shutter speed
• Electronic shutter table
• Pulse width control
[Other operation modes]
• Scanning system
[Level setting]
• Gain setting value
• Offset setting value
[Configuration]
• Manu display
• BZ
• Baud rate
• Vinit2 polarity
• Test pattern
• Continuous strobe signal =OFF
• Vsub voltage
Fig. 6-4 Setting contents immediately after reading out
factory default
[Procedure a. (to retrieve default onto RAM)]
<Step 1>
Set the mode switch to the position "9", and manipulate the UP/DOWN switch either upward or downward.
Then, turn on the power and keep the position of the UP/DOWN switch for several seconds.
<Step 2>
Return the UP/DOWN switch to the neutral position when the response sound of "pip-pip" is heard and
LED flashes in orange.
<Step 3>
For execution, apply an upward or downward stroke to the UP/DOWN switch once again. For cancellation,
turn off the power to the camera.
<Step 4>
The camera automatically restarts and the operation mode is set to be Group 1.
(Note) To save the read data, set the mode switch to "A" (or other page corresponding to the data to be saved) and apply
an upward stroke to the UP/DOWN switch (save to the program page).
Be ready for switching between
continuous shutter operation and
asynchronous shutter operation.
Temporarily switch to continuous
shutter operation
Set shutter speed to 1/250 sec.
Be ready for changing gain.
Set gain while checking image.
Be ready for switching between
continuous shutter operation and
asynchronous shutter operation.
Switch
to
asynchronous
operation.
Be ready for saving in program page.
Save setting in program page A.
= Continuous
= High speed
= Content of (Table 6-1)
= DISABLED
= Normal scan
= (Factory default)
= (Factory default)
= ON
= ON
= 9600bps
= NORMAL (negative logic)
= OFF
= (Factory default)
(Example 1) This is the procedure for setting the gain for the
asynchronous shutter operation (1/250 sec.).
[Explanation]
The left example of the setting procedure is for using the
camera in the asynchronous shutter operation. In the left
example, the operation mode is temporarily set to be the
continuous shutter operation because this makes it easier to
set the gain and others. In the case where the image output
state can be easily checked by way of repeatedly inputting
external trigger signal (Vinit) from a user device, the
operation mode should be set to be "Asynchronous Shutter"
from the beginning before setting the gain and others.
(Note) When the pulse width control mode is set for the
asynchronous shutter operation, the above described
method in which the continuous shutter mode is
temporarily set cannot be used (because the shutter
shutter
speed at the position "9" for the asynchronous shutter
mode is different from that for the continuous shutter
mode). If the camera is used in the pulse width
control mode, it is necessary to set the asynchronous
shutter operation and then set the gain and others
while actually inputting the trigger signal (Vinit) from a
user device.
(!)
This equipment is designed so that the pulse width
control mode can be set to OFF even when it is in the
asynchronous shutter mode and the mode switch is at
the position "9". (Default condition)
This procedure is for reading out the factory default in order to
initialize the setting that was changed by the user after purchase.
With this equipment, the following 2 different procedures are
selectable for the readout:
a. The factory default is retrieved onto the internal RAM of the
camera.
b. The factory default is retrieved onto the internal RAM of the
camera and written into the all program pages.
(Note) When the procedure a. is selected, the "storage page for
factory default" that is located separately from the memory
for automatic loading at the time of power-on (program
pages from "A" to "F") is loaded and the camera is started
up. In this case, the data is just read out to the internal RAM
of the camera. If it is necessary to use the camera with the
factory default values after the power is turned off, those
must be saved in the program pages from "A" to "F".
When the procedure b. is selected, the parameters that were
read out are automatically saved in the program pages from
"A" to "F". Carefully note that the earlier setting data that
were saved by the user are all overwritten and lost.