STICK OPERATION

STARTING METHODS
Scratch/Match Method
Tapping Method
1. Turn on unit. Allow unit to cycle through its start up program.
2. Select the Stick icon on the Process Selector.
3. Make sure electrode holder is in in the Positive side and the work clamp is in the negative
connector.
4. Select the Amp level desired. Use table 5 on page 13 to determine approximate amps suita-
ble for the rod size selected. Consult the welding electrode manufacturer's recommendation
as well for proper amperage. No voltage adjustment is available.
5. Use the arc force control to select the desired arc characteristics, creating the desired arc
characteristic and amp response needed to maintain the arc. Cellulose electrodes will require
more arc force control than other rods, but each brand and size will weld a little differently.
The arc force control setting will vary from person to person as well, with different rod angles,
positions, and arc lengths all factoring into the arc force control performance.
6. Strike the arc with either the tapping method or the match strike method. Beginners usual-
ly find that the match strike method yields best results. The Voltage Reduction Circuit may re-
quire more than one strike or tap to fully energize the rod so that the arc will strike properly.