extronics iSCAN101 Operating Instructions Manual

Wired handheld scanner
Hide thumbs Also See for iSCAN101:

Advertisement

Quick Links

Operating Instructions
Wired handheld scanner
iSCAN101
iSCAN101PDF
iSCAN101 2D
Date: 10.08.2015
Extronics Limited  
1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU 
Tel: +44 (0) 845 277 5000  Fax: +44 (0)845 277 4000  E‐mail: info@extronics.com  Web: www.extronics.com 
 
 
Rev 1.1 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iSCAN101 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for extronics iSCAN101

  • Page 1 Operating Instructions Wired handheld scanner iSCAN101 iSCAN101PDF iSCAN101 2D Date: 10.08.2015 Extronics Limited   1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU  Tel: +44 (0) 845 277 5000  Fax: +44 (0)845 277 4000  E‐mail: info@extronics.com  Web: www.extronics.com      Rev 1.1 ...
  • Page 2: Table Of Contents

    – connection with cable end sleeve ....................15   Direct connection of the handheld scanner without plug connection to the power supply with USB   interface – connection with cable end sleeve ....................16   Extronics Limited   1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU  Tel: +44 (0) 845 277 5000  Fax: +44 (0)845 277 4000  E‐mail: info@extronics.com  Web: www.extronics.com      1 ...
  • Page 3: Important Notes On The Operating Instructions

    Warnings are highlighted by a special symbol and a different font colour: Non-compliance may result in life-threatening situations. This warning must be heeded. Danger This type of warning concerns dangerous situations that may result in minor injuries. Warning Important and helpful notes and information. Info Extronics Limited   1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU  Tel: +44 (0) 845 277 5000  Fax: +44 (0)845 277 4000  E‐mail: info@extronics.com  Web: www.extronics.com      2 ...
  • Page 4: Notes On The Operating Instructions

    The notes contained in this manual are important for starting up and operating the product. These instructions may be updated at any time. Extronics Limited reserves the right to make changes to this document.
  • Page 5: General Notes Of Caution

    (e.g. RL 99/92/EG, RL 94/9EG, or the national rules such as IEC 60 079-14 and VDE 0100).  In the hazardous area it is the operator's responsibility to carry out any repair and maintenance in compliance with applicable rules. Extronics Limited   1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU  Tel: +44 (0) 845 277 5000  Fax: +44 (0)845 277 4000  E‐mail: info@extronics.com  Web: www.extronics.com   ...
  • Page 6 Software installation For instructions on how to install the software at the PC please refer to the manual issued by SICK. Operation Before operating the device you must ensure that all necessary components are available. Extronics Limited   1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU  Tel: +44 (0) 845 277 5000  Fax: +44 (0)845 277 4000  E‐mail: info@extronics.com  Web: www.extronics.com           5 ...
  • Page 7: Product Information

    Midpoint 18 Middlewich CW10 0HU Devices iSCAN1x1 iSCAN1x1PDF iSCAN1x1 2D iSCAN101 and iSCAN101PDF 2.2  Explosion              protection  II 2G Ex ib IIC T4 II 2G Ex ib IIC T4 Gb II 2D Ex ib IIIC T135C II 2D Ex ib IIIC T135C Db...
  • Page 8: Technical Data

    2.3  Technical data  RS232 5.6V version:  maximum input voltage 5.6 V  maximum input current 480 mA  maximum input power 1.25 W  maximum internal inductance negligible  maximum internal capacitance C 46 µF Note: The input voltage in to the handheld scanner itself is reduced by the associated connection cable ISCAN101CAB5 or 6 from 5.6V to 4.9V.
  • Page 9 2D RS232 4.9V version:  maximum input voltage 4.9 V  maximum input current 750 mA  maximum input power  maximum internal inductance negligible  maximum internal capacitance Ci 202 µF USB version:  maximum input voltage 4.9 V ...
  • Page 10 -20°C to +50°C Storage temperature -30°C to +70°C Weight ca. 200g (without connection cable) Optional interfaces RS-232 TTL / USB Terminal assignment USB cable (Handheld scanner) USB/D+ green USB/D- white GND black +UB brown Extronics Limited   1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU  Tel: +44 (0) 845 277 5000  Fax: +44 (0)845 277 4000  E‐mail: info@extronics.com  Web: www.extronics.com           9 ...
  • Page 11: Combinations

    2.6   Application  The scanner is a handheld device. Its purpose is the portable capture and direct transfer of data in hazardous areas. The device has been designed for use in hazardous areas zones 1 and 21. Extronics Limited   1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU  Tel: +44 (0) 845 277 5000  Fax: +44 (0)845 277 4000  E‐mail: info@extronics.com  Web: www.extronics.com   ...
  • Page 12: System Assembly

    The warnings and notes of caution contained in these operating instructions and in the manual issued by SICK AG (www.SICK.com) must be adhered to. For the professional use of the power supply iSCANPS the operating instructions of the manual of the power supply are necessary. Extronics Limited   1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU  Tel: +44 (0) 845 277 5000  Fax: +44 (0)845 277 4000  E‐mail: info@extronics.com  Web: www.extronics.com   ...
  • Page 13: Cable Range In System Assembly

    3.2  Cable range in system assembly  iSCAN101 and iSCAN101PDF 1.8 or 3.8m or optional with RS232 iSCAN101 iSCANPS Up to 20m Host 4.5m or 6m extension iSCAN101 1.8 or 3,8 m iSCANPS Up to 5m Host iSCAN101 2D 1.8 or 3.8m or optional with...
  • Page 14: Step By Step Guide On Installation And Operation

    Cable connected to the wired handheld scanner Insert the plug of the connection cable into the power supply's plug connector. Ensure that the connection is fully secured with the screw cap after the plug has been inserted. Extronics Limited   1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU  Tel: +44 (0) 845 277 5000  Fax: +44 (0)845 277 4000  E‐mail: info@extronics.com  Web: www.extronics.com     ...
  • Page 15: Step 2 - Connection Of Iscanps Power Supply

    Handheld scanner RS232 cable Power supply Wire number Terminals pin assignment Definition Terminal number Definition connection coupling Pin assignment Handheld scanner USB cable Power supply Wire number Terminals pin assignment Definition Terminal number Definition connection coupling Extronics Limited   1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU  Tel: +44 (0) 845 277 5000  Fax: +44 (0)845 277 4000  E‐mail: info@extronics.com  Web: www.extronics.com           14 ...
  • Page 16: Direct Connection Of The Handheld Scanner Without Plug Connection To The Power Supply With Rs232 Interface - Connection With Cable End Sleeve

    Power supply RJ45 pin Connection Wire assignme Definition terminal power Definition colours supply White Brown Yellow intrinsically safe connection box of the ISCANPS RS232 power supply after removal of the wires of the plug connection Extronics Limited   1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU  Tel: +44 (0) 845 277 5000  Fax: +44 (0)845 277 4000  E‐mail: info@extronics.com  Web: www.extronics.com           15 ...
  • Page 17: Direct Connection Of The Handheld Scanner Without Plug Connection To The Power Supply With Usb Interface - Connection With Cable End Sleeve

    RJ45 pin Connection Wire Definitio assignm terminal power Definition colours supply Green White Black Brown intrinsically safe connection box of the ISCANPS USB power supply after removal of the wires of the plug connection Extronics Limited   1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU  Tel: +44 (0) 845 277 5000  Fax: +44 (0)845 277 4000  E‐mail: info@extronics.com  Web: www.extronics.com           16 ...

This manual is also suitable for:

Iscan101pdfIscan101 2d

Table of Contents