– connection with cable end sleeve ....................15 Direct connection of the handheld scanner without plug connection to the power supply with USB interface – connection with cable end sleeve ....................16 Extronics Limited 1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E‐mail: info@extronics.com Web: www.extronics.com 1 ...
Warnings are highlighted by a special symbol and a different font colour: Non-compliance may result in life-threatening situations. This warning must be heeded. Danger This type of warning concerns dangerous situations that may result in minor injuries. Warning Important and helpful notes and information. Info Extronics Limited 1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E‐mail: info@extronics.com Web: www.extronics.com 2 ...
The notes contained in this manual are important for starting up and operating the product. These instructions may be updated at any time. Extronics Limited reserves the right to make changes to this document.
(e.g. RL 99/92/EG, RL 94/9EG, or the national rules such as IEC 60 079-14 and VDE 0100). In the hazardous area it is the operator's responsibility to carry out any repair and maintenance in compliance with applicable rules. Extronics Limited 1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E‐mail: info@extronics.com Web: www.extronics.com ...
Page 6
Software installation For instructions on how to install the software at the PC please refer to the manual issued by SICK. Operation Before operating the device you must ensure that all necessary components are available. Extronics Limited 1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E‐mail: info@extronics.com Web: www.extronics.com 5 ...
Midpoint 18 Middlewich CW10 0HU Devices iSCAN1x1 iSCAN1x1PDF iSCAN1x1 2D iSCAN101 and iSCAN101PDF 2.2 Explosion protection II 2G Ex ib IIC T4 II 2G Ex ib IIC T4 Gb II 2D Ex ib IIIC T135C II 2D Ex ib IIIC T135C Db...
2.3 Technical data RS232 5.6V version: maximum input voltage 5.6 V maximum input current 480 mA maximum input power 1.25 W maximum internal inductance negligible maximum internal capacitance C 46 µF Note: The input voltage in to the handheld scanner itself is reduced by the associated connection cable ISCAN101CAB5 or 6 from 5.6V to 4.9V.
Page 9
2D RS232 4.9V version: maximum input voltage 4.9 V maximum input current 750 mA maximum input power maximum internal inductance negligible maximum internal capacitance Ci 202 µF USB version: maximum input voltage 4.9 V ...
Page 10
-20°C to +50°C Storage temperature -30°C to +70°C Weight ca. 200g (without connection cable) Optional interfaces RS-232 TTL / USB Terminal assignment USB cable (Handheld scanner) USB/D+ green USB/D- white GND black +UB brown Extronics Limited 1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E‐mail: info@extronics.com Web: www.extronics.com 9 ...
2.6 Application The scanner is a handheld device. Its purpose is the portable capture and direct transfer of data in hazardous areas. The device has been designed for use in hazardous areas zones 1 and 21. Extronics Limited 1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E‐mail: info@extronics.com Web: www.extronics.com ...
The warnings and notes of caution contained in these operating instructions and in the manual issued by SICK AG (www.SICK.com) must be adhered to. For the professional use of the power supply iSCANPS the operating instructions of the manual of the power supply are necessary. Extronics Limited 1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E‐mail: info@extronics.com Web: www.extronics.com ...
3.2 Cable range in system assembly iSCAN101 and iSCAN101PDF 1.8 or 3.8m or optional with RS232 iSCAN101 iSCANPS Up to 20m Host 4.5m or 6m extension iSCAN101 1.8 or 3,8 m iSCANPS Up to 5m Host iSCAN101 2D 1.8 or 3.8m or optional with...
Cable connected to the wired handheld scanner Insert the plug of the connection cable into the power supply's plug connector. Ensure that the connection is fully secured with the screw cap after the plug has been inserted. Extronics Limited 1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E‐mail: info@extronics.com Web: www.extronics.com ...
RJ45 pin Connection Wire Definitio assignm terminal power Definition colours supply Green White Black Brown intrinsically safe connection box of the ISCANPS USB power supply after removal of the wires of the plug connection Extronics Limited 1 Dalton Way, Midpoint 18, Middlewich, Cheshire, UK. CW10 0HU Tel: +44 (0) 845 277 5000 Fax: +44 (0)845 277 4000 E‐mail: info@extronics.com Web: www.extronics.com 16 ...