Transducer; Wiring Of Converter Connector For Water Temperature Sensor; Wiring Of Converter Connector For Water Temperature/Speed Sensor - Furuno GP-1650WF Installation & Maintenance

Hide thumbs Also See for GP-1650WF:
Table of Contents

Advertisement

2. WIRING
Antenna unit
Connect the antenna unit cable to the ANT connector.

Transducer

Connect the transducer cable to the XDR connector. Connect the water temperature sensor
(option) or water temperature/speed sensor (option) to the XDR connector with the
converter connector (Type : 02S4147, Code No. : 000-141-082, option).
MJ-A6SRMD
SHIELD
TEMP
TEMP0V
NC
NC
NC
MJ-A10SRMD
NC
NC
NC
NC
NC
NC
NC
XDR+
XDR SHIELD
XDR-

Wiring of converter connector for water temperature sensor

MJ-A6SRMD
SHIELD
TEMP
TEMP0V/SPD0V
SPD
+V
NC
MJ-A10SRMD
NC
NC
NC
NC
NC
NC
NC
XDR+
XDR SHIELD
XDR-

Wiring of converter connector for water temperature/speed sensor

2-2
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
10
MJ-A10SPF
1
SPD
4
TEMP
7
GND
3
GND
2
+12V
5
NC
6
NC
8
XDR-P
9
XDR-SHIELD
10
XDR-M
MJ-A10SPF
4
TEMP
7
GND
3
GND
1
SPD
2
+12V
5
NC
6
NC
8
XDR-P
9
XDR-SHIELD
10
XDR-M

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gp-1650wdfGp-1850wfGp-1850wdf

Table of Contents