4. INCORPORATION OF DGPS BEACON RECEIVER KIT (for GP-1650WF)
Cable assy.
S.FL2-2LP0.7-D-WHT (175)
8. Connect cable assy. S.FL2-2LP0.7-D-WHT (121) (supplied) to J3 of the GR-7000A.
9. Close the lid of the GR-7000A.
10. Connect connector assy. PH6P-W-L240 to J2 of GR-7000A (Refer to the figure below).
11. Fasten the GR-7000A (Beacon receiver) to the heat sink with four M3X10 screws
(supplied) as shown in the figure below.
S.FL2-2LPO.7-D-WHT (121)
Connect to
J106 on
MAIN Board.
Cable assy.
S.FL2-2LP0.7-D-WHT (121)

Beacon receiver

Pan-head screw B
M3X10, 4 pcs.
Connect to
J8 on ANLG
Board.
Connect to
J2 on GN-8091.
GN-8091
Heat sink

Installation of DGPS beacon receiver

J1
J3
Notch
Beacon receiver
GR-7000A
Connect to J107
on MAIN Board
Cover of GR-7000A
Beacon receiver board
GR-7000A
Cable assy.
PH6P-W-L240
Notch
4-5