Possible Malfunctions - Bartscher Aurora 22 Instruction Manual

Hide thumbs Also See for Aurora 22:
Table of Contents

Advertisement

o Only a qualified technician and using original spare parts and accessories should
carry out repairs and maintenance of the device. Do not attempt to repair the
device yourself.

7. Possible Malfunctions

PROBLEM
The device is turned on
but the green control
light (brewing indicator)
has not come on.
The coffee machine
shuts off.
The descale indicator is
flashing.
The device is turned on,
the brewing indicator is
on, but hot water is not
flowing out.
The device is turned on,
the brewing indicator
does not come on and
hot water does not flow
out.
Fuse releases right after
turning machine on.
The above described problem cases are given for orientation and as examples.
Should these or similar problems occur, please turn off the machine immediately
and don´t use it anymore. In order to check and repair your machine, please
contact a qualified expert or the manufacturer immediately.
- 34 -
CAUSE
• Plug not connected
correctly
• Fuse of mains opened
• Control lamp defect
• Switch defect
Overheating protection
was triggered.
• The level of calcium
deposits in the coffee
machine has become too
great.
• The main heater is
damaged
• Damaged thermostat
• Control panel damaged
• Damaged filling switch
• Electric short circuit
REMEDY
• Connect plug correctly
• Control fuse, test
machine on other plug
• Contact supplier
• Contact supplier
• Let the coffee machine
cool down and press the
RESET button on the
back of the machine.
• Clean the coffee
machine of deposits
(6.2 „Regular
descaling")
• Contact the supplier
• Contact the supplier
Contact the supplier
Contact the supplier
Contact supplier

Advertisement

Table of Contents
loading

Table of Contents