7

Possible malfunctions

Mögliche
The table below contains descriptions of possible causes and solutions to
malfunctions or errors during operation of the appliance. When malfunction cannot
be removed, contact the technical service.
Problem
The appliance is
switched off, but
the red operation
indicator light in
the ON/OFF switch
does not come on.
When switched on,
the fuse is tripped
immediately.
EN
The appliance is
switched on, the
red operation
indicator light does
not come on and
hot water does not
flow.
20 / 24
Cause
Incorrectly connected plug.
The premises connection
fuse tripped.
Damaged operation
indicator light.
Damaged switch.
Short circuit.
The appliance is scaled.
Too little of brewed liquid.
Damaged level switch.
Possible malfunctions
Solution
Connect the plug.
Disconnect the appliance
from mains supply, reset the
fuse and re-connect the
appliance.
Contact the supplier.
Contact the supplier.
Contact the supplier.
Descale the appliance
following the instructions in
section "Descaling".
Press the RESET button at
the rear side of the
appliance.
Start the appliance.
Observe the minimum
amount of brewed liquid.
Contact the supplier.