Error Symptoms - IBM eserver xSeries 232 8668 Hardware Maintenance Manual

Hide thumbs Also See for eserver xSeries 232 8668:
Table of Contents

Advertisement

Error Code/Symptom
264-XXX-0NN (Failed Tape Drive test)
264-XXX-999 (Errors on multiple tape
drives, see error text for more info)
301-XXX-000 (Failed Keyboard test)
405-XXX-000 (Failed Ethernet test on
controller on the System Board)
405-XXX-00N (Failed Ethernet test on
adapter in PCI slot N)
415-XXX-000 (Failed Modem test)

Error symptoms

Error Symptom
CD is not working properly.
CD-ROM drive tray is not working. (The
server must be powered-on.)
CD-ROM drive is not recognized.
Power switch does not work and reset
button does work.
FRU/Action
1. Tape Cartridge, if user executed the Read/Write Tape Drive test
(XXX = 256)
2. SCSI or Power Cable connected to tape drive with SCSI ID NN.
3. Tape Drive with SCSI ID NN (Refer to the Help and Service
Information appendix of the tape drive's User Guide).
4. System Board or SCSI Controller. (Run SCSI Controller Diagnostic
to determine if the SCSI bus is functioning properly.)
1. See error messages/text in the PC Doctor error log for detailed
information on each individual tape drive error.
1. Keyboard
1. Verify that Ethernet is not disabled in BIOS.
2. System Board
1. Adapter in PCI slot N.
2. System Board
1. Cable
2. Modem
Note: Ensure modem is present and attached to server.
3. System Board
FRU/Action
1. Clean the CD.
2. Run CD-ROM Diagnostic
3. CD-ROM Drive
1. Insert the end of a paper clip into the manual tray-release
opening.
2. Run CD-ROM Diagnostic
3. CD-ROM Drive
1. Run Configuration/Setup, enable primary IDE channel.
2. Check cables and jumpers.
3. Check for correct device driver.
4. System Board
5. Run CD-ROM diagnostics
6. CD-ROM Drive
1. Verify that the power-on control jumper on J23 extension cable is
on pins 1 and 2.
2. Power Switch Assembly
3. System Board
111
Symptom-to-FRU index

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents