ESAB Powercut 900 Instruction Manual page 32

Manual & mechanized plasmarc cutting package
Hide thumbs Also See for Powercut 900:
Table of Contents

Advertisement

SECTION 4
D.
Torch Trigger / gas Test Switch
Operating modes:
Normal Trigger (CENTER position) - Setting will be used for most cutting and gouging operations. Torch switch
must be held in by the operator during the entire cutting operation and then released at the end of cut. Recom-
mended for normal cutting, expanded metal / grate cutting, and gouging.
Trigger Lock (DOWN position) - Allows the torch switch to be released after triggering and the cutting arc has
been initiated. To extinguish the arc at the end of cut, press and release torch switch again or pull torch away
from work. Not recommended for expanded metal / grate cutting.
Test Mode:
gas Test Switch (UP position) - The display screen will indicate flowing air pressure. The air regulator should be
adjusted to recommended pressure before cutting operations. Allow air to flow for a few minutes. This should
remove any condensation that may have accumulated during shutdown period. Be sure to place switch in
Normal Trigger or Trigger Lock position before starting cutting operations.
E. Display Screen: Displays current settings during normal operation.
1. power-up Indication: When unit is initially switched on the Model, PIP (Parts in Place), Software version will be
briefly displayed. Display will then show Current Setting.
2. gas Test: When unit is in the "GAS TEST" mode the display will indicate air pressure setting in psi/bar.
3. fault Indication: Should a fault condition exist in normal operation, the display will show a code number. Refer to
the "Help Code" menu on the front panel (non-"CE" units only) or in Section 4.1.F and in Troubleshooting Section 6.1.
All fault signals will remain on for a minimum of 10 seconds. If fault clears, all will reset automatically
except for over-current. To clear over-current, the power must be shut off for 5 seconds and then turned
Note:
back on.
figure 4-2. powercut 900 Controls
32
OpErATION
E
UP position
CENTER position
D
DOWN position
Toggle Switch detail
F
(Codes shown on
non -"CE" units only)

Hide quick links: