Primary Input Connections - ESAB Powercut 900 Instruction Manual

Manual & mechanized plasmarc cutting package
Hide thumbs Also See for Powercut 900:
Table of Contents

Advertisement

SECTION 3
WArNINg
3.5

primary Input Connections

The Powercut 900 consoles are equipped with approximately 8 ft. (2.4 m) of 4-conductor input power cable for
3 phase connection. If single-phase connection is desired, cap the unused wire on the input power cable per
chart below.
NOTE:
The 208/230 vac, 60 Hz models are equipped with a plug for single-phase connection only. The plug is configured NEMA
6-50P (50A 250 V) and mounted to a 4-conductor cable. If 3-phase connection is desired, remove and discard the plug
and proceed as described above.
NOTE:
If using 208 vac input power, the PC-900 must be reconnected for 208 vac input as directed in Section 3.5.1.
PRIMARY INPUT
POWER CABLE
ELECTrIC SHOCK CAN KILL! prECAUTIONArY MEASUrES SHOULD
BE TAKEN TO prOVIDE MAxIMUM prOTECTION AgAINST ELECTrI-
CAL SHOCK. BE SUrE THAT ALL pOWEr IS Off BY OpENINg THE LINE
(WALL) DISCONNECT SWITCH AND BY UNpLUggINg THE pOWEr
COrD TO THE UNIT WHEN CONNECTIONS ArE MADE INSIDE Of THE
pOWEr SOUrCE.
STANDArD UNITS
(NON-CE)
PHASE
3
1
L1
Black
Black
L2
Red
-
L3
White
White
GND
Green
Green
figure 3-1. Input Connections
CE UNITS
(EUrOpE)
PHASE
3
L1
Brown
L2
Black
L3
Gray
GND
Green/Yel
WArNINg
INSULATE UNUSED pOWEr COrD
CONDUCTOr WHEN CONNECTINg
fOr SINgLE pHASE.
CUSTOMER FUSED LINE DISCONNECT SWITCH
24
INSTALLATION
1
Brown
-
Gray
Green/Yel
(See Table 3-1)