Troubleshooting; Error Messages; Error Codes - DeDietrich AWHP 4 MR User Manual

Reversible air/water "split inverter" heat pump
Hide thumbs Also See for AWHP 4 MR:
Table of Contents

Advertisement

8

Troubleshooting

8.1

Error messages

Fig.51
Restarting the appliance
Fig.52
Error code display
Tab.21 List of alerts
Error code Message
W4
WATPRESSURE
WARNING
W5
SYSTEM FLOW RATE
ALERT
Tab.22 List of lock-downs
Code Message
Description
B00
PARAME­
Incorrect parameter configu­
TER ERROR
ration
B02
TOTAL
The BL input on the terminal
LOCK-
block in the EHC-02 PCB is
DOWN
open
B03
PARTIAL
The BL input on the terminal
LOCK-
block in the EHC-02 PCB is
DOWN
open
B05
WATER
Error on the water pressure
PRESSURE
sensor
S OPEN
B06
WATER
Error on the water pressure
PRESSURE
sensor
S CLOSED
B09
CONFIG ER­
The hybrid system has not
ROR
been configured
7623755 - v02 - 03072015
1. Press
MW-5000060-2
Note
The previous codes are displayed alternately.
In economy mode, the appliance will not run a domestic hot water
heating cycle after a central heating cycle.
2. Briefly press the
the screen.
MW-5000061-2

8.1.1 Error codes

An error code is a temporary boiler status, resulting from the detection of
an anomaly.
Description
Water pressure in the installation lower than the minimum pressure
Flow rate in the installation lower than the minimum flow rate
Check
Contact the professional responsible for maintenance of the heat pump
Contact the professional responsible for maintenance of the heat pump
Contact the professional responsible for maintenance of the heat pump
Contact the professional responsible for maintenance of the heat pump
Contact the professional responsible for maintenance of the heat pump
Contact the professional responsible for maintenance of the heat pump
for 3 seconds to restart the appliance.
key to display the current operating status on