Troubleshooting; Resolving Operating Errors; Types Of Error Code; Error Codes - DeDietrich HPI S User Manual

Reversible air/water "split inverter" heat pump
Table of Contents

Advertisement

6 Troubleshooting

6
Troubleshooting
6.1

Resolving operating errors

Tab.21
Type of code
Warning
Blockage
Lock out
Tab.22
List of temporary error codes
Error
Message
code
H00.17
DHW sensor Closed
H00.32
TOutside Open
H00.33
TOutside Closed
H00.34
TOutside Missing
H00.47
HP flow sensor removed
or below range
H00.48
THp Flow Closed
H00.49
THp Flow Missing
H00.51
THp Return Open
H00.52
THp Return Closed
H00.57
T DHW Top Open
H00.58
T DHW Top Closed
H02.02
Wait Config Number
28
MIT-S
If your appliance malfunctions, the status LED flashes and/or changes
colour and a message containing an error code is displayed on the main
screen of the control panel. This error code is important for the correct and
rapid diagnosis of the type of malfunction and for any technical assistance
that may be needed.
If an error occurs:
1. Make a note of the code displayed on the screen.
2. Remedy the problem described by the error code or contact the
installer.
3. Switch the heat pump off and back on to check that the cause of the
error has been removed.
4. If the code is displayed again, contact the installer.
6.1.1
The control panel can display three types of error codes:
Code format
Axx.xx
Hxx.xx
Exx.xx
6.1.2
An error code is a temporary status, resulting from the detection of a heat
pump anomaly. The heat pump attempts to restart automatically until it
switches on.
When one of the following codes is displayed and the heat pump cannot
restart automatically, contact a maintenance technician.
Description
Domestic Hot Water tank temperature sensor is either shorted or measures a
temperature above range
Outside temperature sensor is either removed or measures a temperature below range
Outside temperature sensor is either shorted or measures a temperature above range
Outside temperature sensor was expected but not detected
Heat pump flow temperature sensor is either removed or measures a temperature
below range
Heat pump flow temperature sensor is either shorted or measures a temperature
above range
Heat pump flow temperature sensor was expected but not detected
Heat pump return temperature sensor is either removed or measures a temperature
below range
Heat pump return temperature sensor is either shorted or measures a temperature
above range
Domestic Hot Water top temperature sensor is either removed or measures a
temperature below range
Domestic Hot Water top temperature sensor is either shorted or measures a
temperature above range
Waiting For Configuration Number

Types of error code

Colour of the status LED
Green flashing
Continuous red
Red flashing

Error codes

7684505 - v03 - 14052020

Hide quick links:

Advertisement

Table of Contents
loading