8. TECHNICAL DATA

Master 5001
Mains voltage
Rated power
Connection cable
Fuse
Loading capacity
Control range for welding current
Max. welding voltage
Open circuit voltage
Open circuit power
Efficiency at nominal values
Power factor
Storage temperature range
Operation temperature range
Temperature class
Degree of protection
External dimensions
(without handles)
Weight
Voltage supply for auxiliary devices
The product meets conformity requirements for CE marking.
14 – MASTER 5001/0541
3~, 50/60 Hz
80 % ED
100 % ED
80 % ED
100 % ED
length
width
height
fuse
400 V ± 10 %
500 A / 25,6 kVA
440 A / 20,2 kVA
4 x 6S - 5 m
35 A delayed
500 A / 40 V
440 A /37,6 V
10 A ... 500 A
50 V / 500 A
68 V
< 75 W
85 %
0,93
- 40 ... + 60 oC
- 20 ... + 40 oC
H (180 oC) / B (130 oC)
IP 23 C
530 mm
230 mm
520 mm
48 kg
50 V DC
1 A / delayed