BURNER RESET
Reset buttons are located behind burner door. The cooker
burner, under normal conditions will flash every 15
seconds. This is part of the system monitoring.
The boiler burner does not flash.
If a fault occurs on either burner then it automatically
shuts down and the red button on the burner control box
will be illuminated.
OPERATE BY PRESSING WITH FINGER ONLY
Please wait at least 60 seconds between resetting the
lockout button.
If for example the storage tank has been replenished after
the oil supply tank ran out, and resetting the lockout
button does not light the burner immediately, it will be
necessary to repeat the sequence.
Continued lockouts indicate a burner or oil supply
malfunction. The fault should be diagnosed and rectified.
BOILER BURNER
RESET KNOB
Fig. 14
OIL LEAK OR FAULT
In the event of repeated failure switch off the oil and
electrical supply to the appliance and contact your
installer/service engineer.
If an oil leak or fault exists or is suspected the unit must
be isolated from the oil and electrical supply. The
appliance must not be used until the fault has been
rectified.
COOKER BURNER
RESET KNOB
DESN 515947
POWER FAILURE
In the event of power failure your appliance will become
inoperative. When the power is restored it will
automatically restart, if programmed or manually set to do
so.
Please endeavour to see that when your fuel is being
delivered to your storage tank, that the appliance is left off
during delivery, and preferably for a period of 1 hour
afterwards to allow sediment within the tank to settle.
This is particularly important for oil systems using two
pipe flow and return.
Also endeavour to avoid running out of fuel, by seeing that
the storage tank is replenished in good time. This will help
avoid nuisance breakdowns which can result through fuel
starvation.
With normal use a boiler/cooker annual flueway clean and
burner maintenance should be carried out immediately
before the end of the heating season.
An additional flueway clean halfway through the heating
season may be necessary in some cases - see servicing
instructions.
A HOT APPLIANCE CANNOT BE SERVICED.
Both cooker and boiler thermostat knobs should be turned
OFF, the night preceding the day of the servicing so that
the appliance will have cooled down by the following
morning.
This product MUST be serviced at regular 12 monthly
intervals
to
optimise
performance.
FAULT INDICATOR
Should a problem arise with the cooker or boiler, an alarm
or a error code fault will be displayed on the RH side for
the cooker and the LH side for the boiler.