Uponor Smatrix Space

Uponor Smatrix Space is a single channel management
system for underfloor heating, and ceiling cooling
installations. It is best used when adding a new zone or
ceiling cooling to an existing underfloor heating system.
3.1
System overview
Uponor Smatrix Space consists of a single channel
controller and a thermostat connected to an 2-way
valve actuator (230 V) and optional component
producing heating/cooling. The controller manages the
operation of the actuator, switching between heating
and cooling when a signal is received, and start/stop
optional heating or cooling when a demand is present.
An Uponor Smatrix Space system is the combination of
a controller:
Uponor Smatrix Space Controller X-161 (controller)
Together with one of the following thermostats:
Uponor Smatrix Wave Thermostat Standard T-165
(standard thermostat T-165)
Uponor Smatrix Wave Thermostat Dig T-166 (digital
thermostat T-166)
Uponor Smatrix Wave Thermostat Prog.+RH T-168
(digital thermostat T-168)
Creating one of the following systems:
Uponor Smatrix Space Cooling
Heating and cooling, with an internal relative
humidity sensor, with an optional external sensor
and scheduling (digital thermostat T-168)
Uponor Smatrix Space PLUS Renovation
Heating and cooling, without a relative humidity
sensor, with an optional external sensor (digital
thermostat T-166)
Uponor Smatrix Space Renovation
Basic heating (standard thermostat T-165)
U P O N O R S M AT R I X S PA C E / S PA C E P L U S · I N S TA L L AT I O N A N D O P E R AT I O N M A N U A L
3.2

Example of a system

The illustration below shows an example of an Uponor
Smatrix Space Cooling installation.
A
B
C
Item
Description
A
Uponor Smatrix Space Controller X-161
B
Uponor Smatrix Wave Thermostat Prog.+RH T-168
with floor sensor
The floor sensor is used for limitation of the floor
temperature, regardless of the room temperature.
The thermostat can also be used with an external
sensor, such as outdoor sensor or a remote sensor
C
2-way valve actuator (230 V)
D
External heating/cooling product (third-party
product, just schematic example in illustration), such
as a 3-way switch over valve.
N O T E !
The floor sensor can be connected to
digital thermostats T-166 and T-168. Floor
temperature limitation is activated in the
thermostat menu system.
For example, the maximum limitation can
protect a sensitive floor covering from
exposure of too high temperature when there
is a high heating demand. The minimum
limitation can keep a tiled floor warm even
when there is a no general demand for heat
supply to the room.