Install Uponor Smatrix Wave Thermostats And Sensors; Placement Of Thermostats; Label Thermostats; Insert Batteries - Uponor smatrix space Installation And Operation Manual

Table of Contents

Advertisement

6
Install Uponor Smatrix Wave thermostats and
sensors
The following thermostats can be connected to the
system:
Uponor Smatrix Wave Thermostat Standard T-165
Uponor Smatrix Wave Thermostat Dig T-166
Uponor Smatrix Wave Thermostat Prog.+RH T-168
6.1

Placement of thermostats

Refer to the installation preparation guidelines (see
section 4.2 Prepare for installation), and use the
following guidelines when positioning the thermostats:
1. Select an indoor wall and a position 1.5 m to 1.8 m
above the floor.
2. Ensure that the thermostat is away from direct solar
radiation.
3. Ensure that the thermostat will not be heated
through the wall from sunshine.
4. Ensure that the thermostat is away from any source
of heat, for example television set, electronic
equipment, fireplace, spotlights, and so on.
5. Ensure that the thermostat is away from any source
of humidity and water splashes (IP20).
1.5–1.8 m
6.2

Label thermostats

Label the thermostats, where suitable, with the ID of
the connected controller (for installations with several
systems), for example, 1, 2, 3 etc.
If the thermostat can connect to an external sensor, add
information about sensor type when applicable.
Available thermostat and sensor combinations:
Room temperature
Room and floor temperature
Room and outdoor temperature
Remote sensor temperature
U P O N O R S M AT R I X S PA C E / S PA C E P L U S · I N S TA L L AT I O N A N D O P E R AT I O N M A N U A L
6.3

Insert batteries

All thermostats use two alkaline 1.5 V AAA batteries
which provides about 2 years of battery life, as long as
they are positioned within radio range of the controller.
Ensure that the batteries are correctly inserted in the
thermostats.
The illustration below shows where to insert them.
6.4
Connect external sensor to
thermostat (optional)
An optional external sensor can be connected to the
thermostats (except the standard thermostat T-165) for
extra functionality.
Connect the sensor to the terminal located at the back
of the thermostat, as shown in the illustration below.
1
2
1. Insert the two wires from the sensor cable (non
polarized) into the removable connector.
2. Tighten the screws fixing the wires in the connector.
3. Insert the connector on the input pegs on the
thermostat.