Uponor smatrix space Installation And Operation Manual page 30

Table of Contents

Advertisement

UK
04 Control mode
In this menu control mode for the thermostat is set.
CZ
If an external sensor is connected to the thermostat, a
control mode must be chosen to accommodate the extra
functionality of the sensor.
DE
Current control mode is displayed (RT, RFT, RS or RO).
To change this setting:
DK
1. Press OK and the parameter starts flashing.
2. Use buttons - or + to change control mode (see list
EE
below).
RT = Room temperature
ES
RFT = Room temperature with external floor sensor
RS = Remote sensor
RO = Room temperature with remote outdoor
FI
sensor*
*)
For display of outdoor temperature only.
FR
3. Press OK to confirm the change and return to the
settings menu.
05 High floor temperature limitation
HR
In this menu a limit on the maximum allowable floor
temperature is set.
HU
This menu is only visible if control mode RFT is activated
in settings menu 04.
To change this setting:
IT
1. Press OK and the parameter starts flashing.
2. Use buttons - or + to change the parameter.
LT
Default: 26 ˚C
Setting range: 20 – 35 ˚C, 0.5 ˚C increments
LV
N O T E !
This parameter cannot be set lower than the
set value in settings menu 06 Low floor
NL
temperature limitation.
3. Press OK to confirm the change and return to the
NO
settings menu.
PL
PT
RO
RU
SE
SK
3 0
06 Low floor temperature limitation
In this menu a limit on the minimum allowable floor
temperature is set.
This menu is only visible if control mode RFT is activated
in settings menu 04.
To change this setting:
1. Press OK and the parameter starts flashing.
2. Use buttons - or + to change the parameter.
3. Press OK to confirm the change and return to the
07 Cooling allowed
In this menu it is set whether cooling is allowed in the
system or not.
To change this setting:
1. Press OK and the parameter starts flashing.
2. Use buttons - or + to toggle between Yes and No.
3. Press OK to confirm the change and return to the
08 Display unit
In this menu temperature display unit is set.
To change this setting:
1. Press OK and the parameter starts flashing.
2. Use buttons - or + to toggle between Celsius and
3. Press OK to confirm the change and return to the
U P O N O R S M AT R I X S PA C E / S PA C E P L U S · I N S TA L L AT I O N A N D O P E R AT I O N M A N U A L
Default: 20 ˚C
Setting range: 10 – 30 ˚C, 0.5 ˚C increments
N O T E !
If this parameter is set lower than 16 ˚C the
cooling icon will start flashing, warning for
risk of condensation in the system.
N O T E !
This parameter cannot be set higher than the
set value in settings menu 05 High floor
temperature limitation.
settings menu.
Yes – shows the cooling demand icon
No – hides the cooling demand icon
settings menu.
Fahrenheit.
DEg ˚C – degrees Celsius
DEg ˚F – degrees Fahrenheit
settings menu.