SAFETY INFORMATION 1. Read this Instruction Manual: Before using the product, please carefully read through the safety information and operation instructions. 2. Keep this Instruction Manual: Safely store the Instruction Manual for future reference. 3. Take note of the “Caution” labels: Please follow the “Caution”...
Page 6
SAFETY INFORMATION Replaced components by the maintenance staff must be official certified parts of identical specifications. Using unauthorized components can cause fire hazards and electric shock damage. 14. Safety inspection: After the unit maintenance has been completed, the maintenance staff must perform safety inspection to ensure proper operation.
Portuguese, French, Japanese, German, Polish and Italian). 21. Support Preset WDR(P0~P66 point) / Preset motion function(P0~ P10 point) (depend on speed dome model) 22. Support Messoa P/D, Pelco P/D, Bosch, Ernitec, GE (Kalatel), and Tyco com munication protocol 2. Important Information Do not point the camera at the sun, as the internal CCD component may be damaged.
FEATURES show up on the image which is not a camera malfunction. Install the unit away from interference sources and please adjust the video cable or reinstall if the screen image results in interference. Please do not remove the serial number label from the unit, as this may invalidate the warranty.
Page 9
FEATURES 1. Video out 2. Alarm in 3. Alarm out 4. AC24V power in 5. Black: AC+ / White: AC– 6. RS485 signal cable 7. Orange: Data+ / White: Data–...
CONNECTIONS AND SETUP 5. Connections and setup G N D (B lack) A la rm In 1 ( B row n) A larm In 2 ( R ed) A larm In 3 ( O range ) A larm In 4 ( Y ellow ) A la rm In 5 ( G reen) A larm In 6 ( B lue) G N D (P urple)
Page 11
CONNECTIONS AND SETUP G N D (B lack) A larm In 1 (B row n) A larm In 2 (R ed) A larm In 3 (O range) A larm In 4 (Y ellow ) A la rm In 5 (G reen) A larm In 6 (B lue) G N D (P urple) G N D (G rey)
6.1 Activate OSD Menu: Method to activate the OSD menu may differ with the connected keypad controller. For keypad controller that is compatible with Pelco P / Pelco D (Messoa-P/Messoa-D), press the key to enter the main menu screen. 6.2 Horizontal Pan/Vertical Tilt:...
OPERATION INSTRUCTIONS recievied (e.g. horizontal rotate, vertical rotate, IRIS, and focus etc.) (b). When the san range has been set: The camera will rotate horizontally in the scan range until a command from the keypad controller is received (e.g. horizontal rotate, vertical rotate, iris, and focus etc.) For configuring the scan range, please use the menu command <PAN/TILT SETUP>...
OPERATION INSTRUCTIONS Note: Please use the menu command <PAN/TILT SETUP> STOP TIME (P0) to configure the stop time, range from 5 sec to 120 sec. 6.4 Camera Settings: 6.4.1 FOCUS: Main menu <CAMERA SETUP> menu <FOCUS> menu Description: These focus modes to choose from: - Manual: Use the keys to control the focus.
OPERATION INSTRUCTIONS Adjust Focus setting options: 1. Press the key to enter the main menu screen. 2. Move the cursor to <CAMERA SETUP>, and then press the key to enter <CAMERA SETUP> menu. 3. Move the cursor to <FOCUS>, and then press the key to enter <FO- CUS>...
OPERATION INSTRUCTIONS 6.4.3 AUTO EXPOSURE (AE): Main menu <CAMERA SETUP> menu <AE> menu The aperture can be directly controlled by the keys. Mode: - FULL AUTO: The shutter speed is set at 1/60 sec (NTSC) or 1/50 sec (PAL) and the camera will automatically adjust the aperture according to the amount of outside light.
OPERATION INSTRUCTIONS 6.4.4 ZOOM LIMIT: Description: - Directly set as wide or tele mode. - Zoom levels: X18, X28, X36, X56...up to X432.(depend on lens module) - Max optical zoom level is X36, digital zoom level starts from X36 to X432 (depend on lens module) Menu: Main Menu...
OPERATION INSTRUCTIONS enter <CAMERA SETUP> menu. 3. Move the cursor to ZOOM SPEED, and then press the key to enter zoom speed selection. 4. Move the joystick up/down to choose the zoom speed selection. 5. Press the key to confirm selection, or press the key to cancel selection and exit from the menu screen.
OPERATION INSTRUCTIONS 1. Press the key to enter the main menu screen. 2. Move the cursor to <CAMERA SETUP>, and then press the key to enter <CAMERA SETUP> menu. 3. Move the cursor to <LINE LOCK>, and then press the key to enter <LINE LOCK>...
OPERATION INSTRUCTIONS 4. Press the key to confirm the zone size, and then go to the setup screen for the zone color: Screen display: PRIVACY ZONE COLOR Move the joystick up/down to select the zone color (black or white). 5. Press the key to confirm the zone color and then go to the next zone setting step, or press the key to exit the privacy zone setup mode.
OPERATION INSTRUCTIONS ALARM 1 ALARM 2 DELAY TIME When using the infrared projector: When using the infrared illuminations during nighttime as an auxiliary light source, the infrared activation signal can be connected to the alarm input port and set the alarm action to BW mode.
OPERATION INSTRUCTIONS 5. Press the key to confirm selection, or press the key to cancel selection and exit from the menu screen. 6.5.2 Proportional P/T: Proportional P/T enabled to let the camera to adjust the horizontal pan/vertical tilt speed according to the zoom level. When zoomed in, the horizontal and vertical speed will be slowed down so as to keep the image from moving too rapidly.
OPERATION INSTRUCTIONS 3. Move the cursor to the SCAN LIMIT STOPS selection and then press the key to enter. 4. Move the joystick up/down to choose ON or OFF. 5. Press the key to confirm selection, or press the key to cancel selection and exit from the menu screen.
OPERATION INSTRUCTIONS position, then press number key “91” + hold the key for 2 seconds. The screen will show: MANUAL RIGHT LIMIT, and the right limit will be set. 6.5.5 RECOVER TIME: Under scan mode (auto, frame, random), if the auto patrol and pattern patrol are interrupted from inadvertent keypad controller input, the camera will resume the previous action after a set amount of time.
OPERATION INSTRUCTIONS enter <PAN/TILT SETUP> menu. 3. Move the cursor to the SCAN SPEED selection and then press the to enter. 4. Move the joystick up/down to set the speed. 5. Press the key to confirm selection, or press the key to cancel selection and exit from the menu screen.
OPERATION INSTRUCTIONS Set the Max Speed: 1. Press the key to enter the main menu screen. 2. Move the cursor to <PAN/TILT SETUP>, and then press the key to enter <PAN/TILT SETUP> menu. 3. Move the cursor to the MAX SPEED selection and then press the to enter.
OPERATION INSTRUCTIONS 6.6 TITLE: Main Menu <CAMERA TITLE> Menu Set the Title: 1. Press the key to enter the main menu screen. 2. Move the cursor to <CAMERA TITLE>, and then press the key to enter <CAM- ERA TITLE> menu. 3.
OPERATION INSTRUCTIONS Main Menu <PRESET SETUP> menu *Before activating the auto patrol feature, please refer to Chapter 8 Configure preset points to configure the desired patrol points* Activate the Auto Patrol: 1. Press the key to enter the main menu screen. 2.
OPERATION INSTRUCTIONS 4. Move the joystick up/down to choose the position, and left/right to set preset speed. 5. Press the key to confirm selection, or press the key to cancel selection and exit from the menu screen. 6.7.3 TITLE: Main menu <PRESET SETUP>...
OPERATION INSTRUCTIONS Activate the Preset WD: 1. Press the key to enter the main menu screen. 2. Move the cursor to <PRESET SETUP>, and then press the key to enter <PRESET SETUP> menu. 3. Move the cursor to the PRESET WD selection and then press the to enter.
OPERATION INSTRUCTIONS 10. Move the joystick up/down to choose the threshold LEVEL selection, and left/ right to set HI, MID or LOW. 11. Move the joystick up/down to choose the INTERCAL TIME selection, and left/ right to set the time. 12.
OPERATION INSTRUCTIONS Set the Tilt Angle: 1. Press the key to enter the main menu screen. 2. Move the cursor to <OTHERS>, and then press the key to enter <OTHERS> menu. 3. Move the cursor to the SCAN TILT ANGLE selection and then press the key to enter.
OPERATION INSTRUCTIONS 6.8.4 MOTION DETECTION: (For WDR model only) You can set motion area to detect moving objectives. You can create and move up to 4 motion areas from display. The motion detection is active as camera rotates. Main menu <OTHERS>...
OPERATION INSTRUCTIONS enter. 4. Move the joystick up/down to set the week. 5. Press the key to confirm selection, or press the key to cancel selection and exit from the menu screen. 6.9.2 TIME: Main menu <SYSTEM> menu LANGUAGE ENGLISH ACTION AUTO RETURN Set the Time:...
OPERATION INSTRUCTIONS <PASSWORD> menu. 4. Move the cursor to PASSWORD ENABLE and press the key to enter the option. Use the joystick up/down to set ON or OFF. 5. If ON is selected, please enter the password. Press the key to enter the PASSWORD menu.
OPERATION INSTRUCTIONS 5. Press the key to confirm selection, or press the key to cancel selection and exit from the menu screen. 6.9.5 LOAD FACTORY DEFAULT: Main Menu <SYSTEM> menu LANGUAGE ENGLISH ACTION AUTO RETURN Load the Factory Default: 1. Press the key to enter the main menu screen.
OPERATION INSTRUCTIONS 4. Move the joystick up/down to set ON or OFF. 5. Press the key to confirm selection, or press the key to cancel selection and exit from the menu screen. 6.9.7 MIRROR: Main Menu <SYSTEM> menu LANGUAGE ENGLISH ACTION AUTO RETURN Set Mirror mode:...
OPERATION INSTRUCTIONS Set the language: 1. Press the key to enter the main menu screen. 2. Move the cursor to <SYSTEM>, and then press the key to enter <SYSTEM> menu. 3. Move the cursor to the LANGUAGE selection and then move the joystick up/down to set language.
OPERATION INSTRUCTIONS 6.10 PATTERN TOUR: This camera provides 4 sets of patterns and playback modes for selection. Actions for playback include lens zoom, horizontal pan, and vertical tilt etc. Once the pattern is recorded, it can be played back accordingly to the user’s discretion.
MENU INDEX 7.2 Menu Settings Table: Main Menu Submenu 1 Submenu 2 Contents Factory default CAMERA FOCUS MODE MANUAL, AUTO, IN ICR ON MODE, ONE PUSH AF, AUTO SETUP INTERVAL, ZOOM TRIGGER ACTIVE TIME 0~255 S INTERVAL TIME 0-255 S SENSITIVITY LOW, NORMAL NORMAL...
Page 42
MENU INDEX PRESET AUTO PATROL P0 ~ 255: ON/OFF P0, OFF SETUP PRESET SPEED P0 ~ 255: 30~MAX P0, MAX TITLE PRESET TITLE INPUT 256 POSITION, 20 CHARACTERS (MAX) TITLE POSITION UP/DOWN PRESET WD P0~66: OFF/BLC/WDR PRESET MOTION PRESET MOTION P0 ~ 10: ON, OFF P0, OFF MOTION AREA...
Please refer to the following table for the button combinations and the corresponding functions. The following commands are for use with keypad controllers: Messoa-P, Messoa-D, Pelco P, Pelco D, Bosch, and Ernitec protocol. Number + Key Press...
Page 44
<Open menu screen> press number key 95 then press and hold the PRESET key for 2 seconds (c). Different keypad controllers may have different preset button combinations. Please refer to the instruction manual for key combinations; the above example is the standard setup for controller PELCO P/ PELCO D (MESSOA-P/MESSOA-D).
Page 45
PRESET COMMANDS The following commands are for use with DVR Tyco Protocol Command Description DVR Tyco Name Pan Left Pan left (24°/sec) until Pan Pan Right Pan right (24°/sec) until Pan Stop Pan Stop Stop Panning Tilt Up Tilt up until Tilt Stop Tilt Down Tilt down until Tilt Stop Tilt Stop...
INSTALLATION INSTRUCTIONS 9. 1 Installation Instructions 9.1.1 Pendant Pipe Mount Ceiling Support Frame Installation Instructions (1) Remove the ceiling support frame and attach the connector ring to the aluminum tube in clockwise direction. (2) Mark the ceiling with regards to the 4 mount holes on the ceiling support frame. (3) Drill 4 holes of diameter φ6mm, depth 20mm.
INSTALLATION INSTRUCTIONS 9.1. 2 Wall Mount Wall Hang Support Installation Instructions (1) Remove the secure plate and drill 4 holes on the wall matching the mount holes on the plate. Diameter φ3/8” (9.5mm), depth 1/1/2” (40mm). (2) Hammer 4 screw mounts into the holes and then secure the plate with a hex driver.
INSTALLATION INSTRUCTIONS 9.1.3 Wall Mount With Power Box U-Shape Water-Proof Box Installation Instructions (1) Attach the mounting holes guide onto the wall. (2) Drill 4 holes on the wall matching the mount holes on the plate. Diameter φ3/8” (9.5mm), depth 1/1/2” (40mm) (Figure 1). (3) Hammer 4 screw mounts into the holes.
Page 52
INSTALLATION INSTRUCTIONS Figure 5 Figure 6 ALARM IN CONTROL PANEL ETHERNET CABLE ALARM OUT TO AC 90~260V AC ADAPTER IN AC ADAPTER OUT TO SPEED DOME CABLE AC - AC ADAPTER POWER PLUG Wiring Diagram...
INSTALLATION INSTRUCTIONS 9.1.4 Pendant Pipe Mount With Power Box L-Shape Water-Proof Box Installation Instructions (1) Attach the mounting holes guide onto the wall. (2) Drill 4 holes on the wall matching the mount holes on the plate. Diameter φ3/8” (9.5mm), depth 1/1/2” (40mm) (Figure 1). (3) Hammer 4 screw mounts into the holes.
Page 54
INSTALLATION INSTRUCTIONS Figure 2 Figure 3 Dimensions Diagram Figure 4 Figure 5 Figure 6 ALARM IN CONTROL PANEL ETHERNET CABLE ALARM OUT TO AC 90~260V AC ADAPTER IN AC ADAPTER OUT TO SPEED DOME CABLE AC - AC ADAPTER POWER PLUG...
INSTALLATION INSTRUCTIONS 9.1.5 Parapet Wall Mount Daughter Wall Installation Instructions (1) Remove the secure plate and drill 8 holes on the wall matching the mount holes on the plate. Diameter φ3/8” (9.5mm), depth 1/1/2” (40mm) (Figure 1). (2) Hammer 8 screw mounts into the holes and then secure the plate with a hex driver (Figure 2).
INSTALLATION INSTRUCTIONS 9.1.6 Pole Mount Tube Support Installation Instructions (1) Thread the metal strap through the rectangular holes on the corner support (Figure 1). (2) Use a Philips screwdriver to tighten the metal strap, and then line up the holes on the water-proof box to the holes on the support. Use a hex driver to secure in a clockwise direction (Figure 2).
INSTALLATION INSTRUCTIONS 9.1.7 Corner Mount Corner Support Installation Instructions (1) Drill 4 holes on the wall of diameter φ3/8” (9.5mm), depth 1-1/2” (40mm). (2) Hammer screw mounts into the drilled holes (Figure 1). (3) Line up the holes on the water-proof box to the holes on the support, and use a hex driver to secure in the clockwise direction (Figure 2).
INSTALLATION INSTRUCTIONS 9.1.8 Extension Pole Extension Pole Installation Instructions (1) Remove the extension pole and connector ring. (2) Secure the connector ring to the original connection unit in the clockwise direction (Figure 1). (3) Secure the extension pole to the connector ring and use a hex driver to secure the stop screws in place (Figure 2).
INSTALLATION INSTRUCTIONS 9.1.9 Sun Shield Sun Shield Installation Instructions (1) Remove the sun shade. (2) Place the sun shade over the main unit from above (Figure 1). (3) Use a hex driver to secure the screw to the connector ring clockwise (Figure 2). (4) Installation completed (Figure 3).
INSTALLATION INSTRUCTIONS 9.1.10 In-Ceiling Mount Suggest to power on the speed dome beyond -5°C (-23°F) or it would need 2~5 minutes to warm up before powered on (1) Remove four tapes from dome cover then open the dome cover counterclockwise. Please refer to Figure 1. (2) Remove the pink EPE and the tapes on iron hooks.
DIP SWITCH SETTINGS SW1: Camera address setup SW pin # SW pin # Address Address on off off off off off off off on on off off on on off off off on off off off off off off off off on off on on off off on on off off off off off off on off on off on on off off off off on off off off off off...
Page 64
254 off on on on on on on on off on off off on on off off 255 on on on on on on on on W2: Communication protocol / Baud rate / Terminal resistance: SW pin# Messoa-P Messoa-D Pelco-P Pelco-D Comm.
SPECIFICATIONS 18X High-speed Dome 28X High-speed Dome 36X High-speed Dome Model Camera Camera Camera Image system NTSC/PAL Lens Image Sensor 1/4” SONY Exview HAD CCD Optical zoom F-Stop Range F1.4 ~ F3.0 F1.35 ~ F3.7 F1.6 ~ F4.5 Focal length (Wide~Tele) 4.1mm ~ 73.8mm 3.5 mm ~ 98 mm f=3.4 mm ~ 122.4 mm...
Page 66
Alphanumerical Dome OSD setup protection Other Superior Super Fine Pan for 0.02° Accuracy / Motion Detection / Scheduling Functions Remote control Remote control MESSOA P/D (Also support Pelco-P/D,GE-Kalatal, Bosch, Ernitec,Tyco) Special Commands support absolute(X , Y , Z) position Interface RS485 (2-wire) Baud Rate...
Page 67
SPECIFICATIONS Network & Digital Video (Network High-Speed Dome Only) Video Compression H.264/MPEG-4/MJPEG Full D1 (720x480 in NTSC, 720x576 in PAL), CIF (352x240 in NTSC, 352x288 in Picture Resolution PAL), QCIF (160x112 in NTSC, 176x144 in PAL) Bit Rate 28K ~ 3M bps Image Frame Rate NTSC: 30fps at full D1 resolution, PAL: 25fps at full D1 resolution Multi-stream...
Need help?
Do you have a question about the ZEIM-4000604G A.1 and is the answer not in the manual?
Questions and answers