Clearances; Hearths; Mantles And Recesses - Realfires RF1200TW Installation Manual

Table of Contents

Advertisement

Clearances

The fire must be installed with the shown minimum clearances to combustible materials

Hearths

Although a hearth is not required, if the fire is installed within 00 mm of the floor, Real Fires does recommend that
protection is given to any combustible flooring directly in front of the fire. The fire produces a large amount of radiant heat
and this might cause damage to carpets and furnishings that are too close.

Mantles and Recesses

A timber mantle may be installed above this appliance but must be within the grey area shown here. If the fire is to be
installed into a recess or with a non-combustible mantle the recess must comply with the following limitations.
If the fire is installed to an external wall then the 00 mm for a combustible mantle can be reduced to 100 mm.
MANTLE MUST NOT
EXTEND BEYOND
THIS AREA
FOR SIDE CLEARANCES, THE
300mm CAN BE REDUCED TO
50mm
Top Trim
45°
X
Mantle
RECESS MUST NOT EXTEND
BEYOND THIS AREA
FIREPROOF BOARD FOR
ANY WALL BELOW RECESS
45°
FIREPROOF BOARD FOR
MINIMUM HEIGHT OF 300 MM
FIREPROOF BOARD OR OTHER
NON-COMBUSTIBLE MATERIAL
NOTE: THE SAME RULES APPLY
TO THE SIDES OF THE FIRE
6
100
WALL
SIDE VIEW
TRIM