  • Page 1 Real Fires Modern Installation Instructions realfi res.co.nz...
  • Page 2 Model 700 Installation Into Existing Masonry Fireplace Ventilation Ventilation to the room that houses the fi re must meet the requirements of NZS5261. Fireplace cavity and chimney inspection Real Fires are designed for installation into an existing masonry fi replace and chimney. Prior to installation the fi...
  • Page 3: Electrical Supply

    Gas supply A suitable gas supply needs to be provided at the right hand rear corner of the fi replace cavity. The pipe sizing should be calculated to supply gas to suit the megajoule rating of the fi re. See rating chart. The gas supply should be reduced down to 10mm copper pipe at the fi...
  • Page 4 Installation instructions - Firebox Once the fi replace cavity has been prepared and the gas supply pipe is positioned at the rear right hand side. The fi rebox can be installed. Note - Electrical options The fi rebox will have two electrical leads from the rear of the fi rebox. All fi reboxes are pre wired for electrical options, Fan and Electric On/O .
  • Page 5: Burner Commissioning

    Installation instructions - Burner into rebox The burner is supplied boxed complete with, fi rebox refl ectors, grate, ash cover, vermiculite, logs, & coals. To make the gas connection, place the burner in the fi rebox so that the back of the burner is touching the back of the fi...
  • Page 6: Optional Fan

    Burner Gas pressure Check burner gas pressure from the test point on the burner supply pipe on the Natural Gas Model and on the injector elbow on the L.P.G. model. See appliance data badge for pressure settings Adjust the pressure at the regulator if required. Check the re is operating correctly and test for spillage of combustion products Optional Fan If a fan has been selected with the fi...
  • Page 7 realfi res.co.nz...
  • Page 8 realfi res.co.nz...
  • Page 9 Real Fires Log and Coal Layout This drawing is a typical example of the log and coal layout on a Real Fire 800. The layout is basically the same for Real Fires Log and Coal Layout all models with logs and coals decreased or increased in width to suit the size of fi re. (The pilot ignition assembly has been omitted from the drawing).
  • Page 10: Framing Details

    Model 700 Installation Into Timber Framing And New Masonry Block Construction New Masonry Block The following instructions are for installation into timber frame. The method of installation is the same for New Masonry Block. See Masonry Block Drawing. Ventilation Ventilation to the room that houses the fi re must meet the requirements of NZS5261 Framing Details Prior to installation, timber framing needs to be provided to suit the selected Real Fire.
  • Page 11 Gas supply A suitable gas supply needs to be provided at the right hand rear corner of the timber frame cavity. The pipe sizing should be calculated to supply gas to suit the megajoule rating of the fi re. See rating chart. The gas supply should be reduced down to 10mm copper pipe at the fi...
  • Page 12: Flue Requirements

    2 metre horizontal clearance from any part of the building, see cowl clearance drawing. Flue and Cowl Size Model Flue Cowl Size Real Fire 650 150mm inner fl ue/ 200mm outer fl ue 150/200 Cowl Real Fire 700 150mm inner fl ue/ 200mm outer fl ue...
  • Page 13 From the positioned fi rebox the fl ue can be assembled. The fl ue is in 1200mm lengths with both inner and outer fl ue. Each fl ue length has a crimped end to join tightly to the next length. Each joint must be securely fi xed by at least three stainless steel rivets.
  • Page 14 Natural Gas burner Fill the burner tray with the vermiculite supplied ensuring the burner tube is completely covered. Lay logs and coals on top of the vermiculite as shown in the log/coal layout drawing. Note that the shelf at the back of the burner is also used.
  • Page 15 Check the re is operating correctly and test for spillage of combustion products Optional Fan If a fan has been selected with the fi re, it will already be fi tted in the fi rebox at the factory. It is controlled by a wall switch, which should be fi...
  • Page 16 realfi res.co.nz...
  • Page 17 realfi res.co.nz...
  • Page 18 realfi res.co.nz...
  • Page 19 Real Fires Log and Coal Layout This drawing is a typical example of the log and coal layout on a Real Fire 800. The layout is basically the same for Real Fires Log and Coal Layout all models with logs and coals decreased or increased in width to suit the size of fi re. (The pilot ignition assembly has been omitted from the drawing).