Electrical Connections - Cornelius VIPER (E) 2 FLAVOR Installation Manual

Hide thumbs Also See for VIPER (E) 2 FLAVOR:
Table of Contents

Advertisement

Viper Installation Manual

Electrical Connections

50Hz and 60Hz units are supplied with the power cord attached. Skip installation information in Table 3 and begin with the
Water Supply Requirements section.
(For reference only, to service the power cord for AC power input, perform the procedure as mentioned in Table 3 )
Step
1
2
3
4
5
6
7
8
9
Publication Number: 621260373INS
Ensure that power to the unit is off. DO NOT plug the power cord into the wall
outlet at this time.
50 Hz unit remove the right side and rear panel from the unit.
60 Hz unit open the merchandiser door to access main electrical box.
Remove the cover from the electrical box.
Feed the power cord through the strain relief, as shown in Figure 5 for 60 Hz
and see Figure 6 for 50Hz.
Pull the slack out of cable and tighten the strain relief (see Figure 5 for 60 Hz
and see Figure 6 for 50 Hz )
Connect the colored wire to the appropriate terminal on the terminal block.
Connect the black wire to the appropriate terminal on the terminal block.
Connect the green wire to the ground terminal next to the terminal block.
Replace the power box cover. DO NOT TURN ON THE POWER at this time.
Figure 5 (60 Hz unit)
Figure 6 (50Hz unit)
Table 3.
Action
Strain Relief
- 10 -
Strain Relief
© 2008-2015, Cornelius Inc.