Viper Installation Manual
Step
1
Select Motor Setup
2
Select the barrel
3
Start calibration
4
Complete the procedure
5
Verify
Publication Number: 621260373INS
BARREL MAINT
SELECT
MANUAL DIAG
TOTALS
BRIX SETUP
12:51P
MOTOR SETUP
MAR 04
SYSTEM
BACK MAIN SETUP
MAINT
GO
Figure 32. Select Screen
Table 19.
Action
Use the Up and Down arrows to highlight MOTOR
SETUP on the Maintenance menu.
Use the Up and Down arrows to highlight the
desired barrel
Press the CAL button at the bottom of the Motor
Setup menu to start the calibration process.
The calibration cycle continues for five (5) minutes
to allow the gearbox to stabilize at temperature
and ensure correct calibration. At that time the
motor stops and it is calibrated.
Press the BACK button at the bottom of the dis-
play to return to the Maintenance menu.
Select SPIN to run the motor and visually ensure
that the calibration reading is 20 +/- 2.
- 34 -
Procedure
© 2008-2015, Cornelius Inc.