Pass-Through Mode

Pass-through mode is a state in which a switch has attempted to join a stack but has been denied primary,
secondary, and idle status. When a switch is in pass-through mode, its Ethernet ports are brought down
(i.e, they cannot pass traffic). Its stacking cable connections remain fully functional and can pass traffic
through to other switches in the stack. In this way, pass-through mode provides a mechanism to prevent
the stack ring from being broken. However, note that when a switch comes up in pass-through mode, it
should not be left unresolved. Pass-through mode is essentially an error state that should be corrected
immediately by the user.
Note. When a switch is in pass-through mode, its information will not display in hardware monitoring
commands such as show chassis, show ni, show module, etc.
Conditions that can trigger a switch to enter pass-through mode include:
Duplicate slot numbers have been assigned within the stack
There are not adequate tokens available for the switch to join the stack (see
The user has manually forced the switch into pass-through mode using the
Note. If a switch is forced into pass-through mode, the rest of the stack will not be disrupted. Any
elements in the stack not operating in pass-through mode continue to operate normally.
The most common reason for one or more switches to enter pass-through is duplicate slot number assign-
ments within the stack. So, in order to avoid pass-through mode, it is useful to keep track of the current
saved slot numbers on all elements in the stack. Slot number assignments are stored in the boot.slot.cfg
file in the /flash directory of each switch.
If the stack is booted and the same slot number is discovered on two or more switches, the switch with the
lowest MAC address is allowed to come up and operate normally. Meanwhile, switches with the duplicate
slot number and a higher MAC address come up in pass-through mode. To check the current slot number
stored in each switch's boot.slot.cfg file, use the
-> show stack topology
NI
Role
----+-----------+--------+------+-------+-------+-------+-------+-------+-------
1 PRIMARY
2 SECONDARY
3 IDLE
In this example, note that both slots 2 and 3 have a saved slot value of 2. If this stack is rebooted, a dupli-
cate slot error will occur and the switch with the lower MAC address will be given the secondary manage-
ment role. The slot with the higher MAC address will be forced into pass-through mode.
OmniSwitch 6800 Series Hardware Users Guide
State
Saved
Link A
Slot
State
RUNNING
1
UP
RUNNING
2
UP
RUNNING
2
UP
July 2005
show stack topology
command. For example:
Link A
Link A
Remote
Remote
Link B
NI
Port
State
3
StackA
UP
1
StackB
UP
1
StackA
UP
Roles Within the Stack
page
3-24)
stack clear slot
command
Link B
Link B
Remote
Remote
NI
Port
2
StackA
3
StackB
2
StackB
page 3-11

Advertisement

Table of Contents
loading

Table of Contents