1.9.1

Hand and arm vibrations

Hand and arm weighted vibration level [m/s²] for HTC 800 Classic have been measured
with equipment approved according to ISO 5349-1:2001. The measurement uncertainty
for the measurement apparatus has been measured as +/- 2%.
The machine has been tested in accordance with ISO 5349-2:2001 and ISO 20643:2005
in order to identify the operations that contribute to the most frequent vibration
exposures. At vibration levels > 2.5 m/s², the exposure time should be limited in
accordance with the table below. For vibration levels > 5 m/s², immediate measures
should be taken by the employer to ensure that the exposure time does not exceed the
time specified in the table below.
Identified work conditions Measured values [m/s²] Daily permitted exposure
Grinding/polishing
Floor preparation (T-rex)
1.9.2

Sound pressure level

This machine has been tested for noise in accordance with ISO 3741. For information
on sound pressure levels, see the table in chapter
4
2,82
3,51
Technical data, page 
HTC 800 Classic
(number of hours)
unlimited
16,2
27.
1.0