1.9

Vibration and noise

Warning!
Always use hearing protection when using the machine.
1.9.1

Hand and arm vibrations

Hand and arm-weighted vibration level [m/s²] for HTC 800 RX have been measured
using equipment approved in accordance with ISO 5349-1:2001. Measurement
uncertainty for the measuring equipment is given as +/- 2%.
The machine has been tested in accordance with ISO 5349-2:2001 and ISO 20643:2005
in order to identify the operations that contribute to the most frequent vibration
exposures. At vibration levels > 2.5 m/s², the exposure time should be limited in
accordance with the table below. For vibration levels > 5 m/s², immediate measures
must be taken by the employer to ensure that the exposure time does not exceed the
time specified in the table below.
Identified work conditions Measured values [m/s²] Daily permitted exposure
Grinding/polishing
Floor preparation (T-rex)
1.9.2

Sound pressure and sound power level

This machine is tested for noise in accordance with ISO 3741 and ISO 11202 . For
information on the sound power level and sound pressure level for each model, see the
table in chapter Technical data, page 39.
2.0
2.95
3.7
(number of hours)
23
14.6
Introduction