The Fuses Trip Frequently - HTC 800 Classic Manual

Hide thumbs Also See for 800 Classic:
Table of Contents

Advertisement

HTC 800 Classic
6.1.5

The fuses trip frequently

The load is too high on the distribution box to which the machine is connected.
Use a different socket or reduce the speed of the machine.
Check the tools. Ensure that the correct tools are used, that they are in working
order and that they are correctly fitted.
6.1.6
The machine cannot cope
Heavy load. Press the handle down slightly so that the grinding head eases
slightly away from the surface being ground.
Sticky coating on the surface being ground. Run half of the machine on the
surface to be cleaned and half on the clean surface. This removes any residue
from the tools.
Check the tools. Ensure that the correct tools are used, that they are in working
order and that they are correctly fitted.
Voltage drop. Check that the cable area meets HTC's recommendations.
Tip!
Check the minimum recommended cable area before using an extension cord.
You will find the recommended cable area under
1.0
Faultfinding
Technical data, page 
27.
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents