Appliance Data And Efficiency - Valor Fires 953 Installer And Owner Manual

Inset live fuel effect gas fire
Table of Contents

Advertisement

2. APPLIANCE DATA AND EFFICIENCY

2.1 General information.
Gas
Inlet Pressure
Input - Max. (Gross)
Input - Min. (Gross)
Inlet Test Pressure (Cold)
Gas Connection
Burner Injector
Pilot & Atmosphere Sensing
Device
Ignition
Aeration
*When converted using kit 0595221.
The appliance information label is located on a plate at the base of the fire. This can
be seen by removing the bottom front cover of the fascia.
2.2 Efficiency.
The efficiency of this appliance has been measured as specified in BS 7977 - 1 and
the result is as below:
Model
953
953 when converted to LPG.
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica
Certification services (0087). The efficiency value may be used in the UK
Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The conversion of net efficiency to gross was achieved by multiplying the net
efficiency by the following conversion factor from Table E3 of SAP 2005, rounding
down to the nearest whole number.
©
Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE
Natural (G20)
20mbar
6.0kW (20,500Btu/h)
2.7kW (9,212Btu/h)
20.0 ± 1.0mbar
(8.0 ± 0.4in w.g.)
8mm pipe
Cat 82 - 069
Copreci Ref. O.D.S
21500/166
Electronic
(Battery 9V PP3)
See section 17.1
Page 8
Propane (G31) *
37mbar
6.1kW (20,800Btu/h)
4.3kW (14,670Btu/h)
37.0 ± 1.0 mbar
(14.85 ± 0.4in w.g.)
8mm pipe
Size 128
Copreci Ref. O.D.S
21500/166 Fitted with RBM
180 - 02 injector
Electronic
(Battery 9V PP3)
Non-adjustable
Efficiency % (Gross)
55
58

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

953 alpha953 eternalObsession953 decadent953 dream

Table of Contents