3. APPLIANCE DATA, EFFICIENCY AND NO x

3.1 General information.

Inlet Pressure
Input - Max. (Gross)
Input - Min. (Gross)
Input - Max. (Net)
Input - Min. (Net)
Inlet Test Pressure (Cold)
Gas Connection
Burner Injector
Pilot & Atmosphere Sensing Device
Under no circumstances is this fire to be converted to LPG. An LPG conversion kit
does not exist for this gas fire.
The appliance information label is located on a 'swing out' plate at the base of the
fire. On fires that are already installed this can be seen by removing the bottom front
cover of the fascia.
©
Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE
Gas
Ignition
Aeration
3.9kW (13,307 Btu/h)
2.3kW (7,848 Btu/h)
3.51kW (11,976 Btu/h)
2.07kW (7,062 Btu/h)
20.0 ± 1.0mbar (8.0 ± 0.4in w.g.)
Copreci Ref. O.D.S 21100/234
Electronic (Alkaline 9V PP3 Battery)
Figure 1.
Page 9
Natural (G20)
20mbar
8mm pipe
Cat 82 - 280
See section 20.1