17.4 To remove the fascia.

1. Remove the firefront casting and the front
cover casting.
2. Detach the control-linking bar from the control
pivot bracket by removing the knurled screw,
which joins the control linking bar to the control
pivot unit (See figure 33).
3. Remove the two screws securing the bottom of
the fascia to the sides of the convection box.
4. Make sure that the control linking bar has
been detached (See point 2 ). Carefully lift the
fascia upward to clear the upper retaining
brackets on the convection box (See figure 34).
Pull the fascia clear and place carefully aside.
5. Refit in the reverse order. Make sure that the fascia is
properly located over the upper retaining brackets. See
section 11 of this guide for detailed fitting instructions.

17.5 To replace the control slide button.

1. Remove the fascia (See section 17.4).
2. Detach the slider control from the fascia by removing
two screws (See figure 35).
3. Detach the control slide button from
the extension bracket by removing two
screws (See figure 36).
4. Replace in the reverse order.
©
Baxi Heating U.K. Limited 2010.
INSTALLER GUIDE
Figure 35. Slider
control removal
Page 37
Figure 33. Control linkage
Figure 34. Fascia
removal
Figure 36.

Hide quick links: